Best bilge pump: what size (GPH) for your boat, and automatic or manual?
Pumps & plumbingFacts verified Page updated
The short answer
For most boats of 18 to 25 ft (5.5 to 7.6 m) the best bilge pump is the Rule 1100 GPH automatic (model 27SA).
It puts more water over the side at a real lift than the pumps it is cross-shopped against: Rule publishes 1005 GPH (3804 L/h) at 3.3 ft (1 m), where Johnson Pump publishes 800 GPH (51 l/min) at 3 ft (0.9 m) for its Ultima Bilge 1250 and SEAFLO publishes 806 GPH (3050 LPH) at 1 m for its 11 Series 1100. Fit the 800 GPH 20SA to a boat under 18 ft (5.5 m) and a 2000 GPH 53S or Rule-Mate with a separate 3700 GPH backup to a cruiser of about 40 ft (12 m), and size on the flow at your discharge height, not on the box: the 2005 edition of ABYC H-22 sets no GPH figure by boat length.
The publisher of this comparison has a commercial relationship with the brand it recommends. Every reason is shown with its source so you can check it. How picks are made
Key facts
Rule publishes delivered flow for its 1100 GPH pumps as 1116 GPH (4224 L/h) at zero head, 1005 GPH (3804 L/h) at 3.3 ft (1 m) and 825 GPH (3123 L/h) at 6.7 ft (2 m), with a maximum head of 10 ft (3 m). Source: xylem.com
ABYC H-22 (2005 edition) sets no minimum bilge pump capacity by boat length. Its rating appendix calls for every electric bilge pump to be rated in gallons per hour at heads of zero, 1 m and 2 m, so pumps can be compared at a real lift. Source: law.resource.org
Rule automatic bilge pumps need no float switch: they switch on for about a second every 2 1/2 minutes, measure the load on the impeller, and keep running until the water is gone. Source: xylem.com
More key facts (3)
Rule states its automatic pumps activate at 5/8 in (1.6 cm) of water and drain down to 1/4 in (0.6 cm), where a standard pump with a float switch lets water reach 2 in (5 cm) before it starts. Source: xylem.com
Rule's automatic range runs from 500 GPH (1893 LPH; 25SA, 3/4 in hose, 4 A fuse) to 4000 GPH (15140 LPH; 56S, 2 in hose, 25 A fuse), in nine models. The 500 and 1100 GPH sizes also come in 24 V (25SA-24, 27SA-24). Source: xylem.com
Rule states that its bilge pumps are for normal amounts of water in an intact boat (spray, rain, seepage, spillage) on craft up to 24 m hull length, and are not intended for damage control or flooding from hull damage. Source: xylem.com
Why Rule over Johnson Pump and SEAFLO
Rule publishes more flow at about 1 m of lift for its 1100 GPH automatic than Johnson Pump publishes for its Ultima Bilge 1250 or SEAFLO for its 11 Series 1100, so on each maker's own figures it moves more water through the thru-hull (through-hull or skin fitting) than pumps with the same or a bigger number on the box. It also switches on at 5/8 in (1.6 cm) of water where Johnson's Ultima Switch waits for 2 in (50 mm), and it switches with no float. Those are the reasons we pick it.
Flow at about 1 m of lift
A pump is bought by the number on the box and used at the height of the thru-hull. On Rule's 1005 GPH figure the Rule 1100 delivers about 200 GPH more at roughly 1 m than the Johnson 1250 or the SEAFLO 1100; on Rule's lower 860 GPH figure it is still 54 to 60 GPH ahead, and at 2 m it is 44 GPH (on 550) to 319 GPH (on 825) ahead of the SEAFLO (our arithmetic). Johnson rates at 3 ft (0.9 m), a little less lift than 1 m, and no two of these figures come from the same test bench.
What backs this up (3)
- ScienceABYC H-22 calls for every electric bilge pump to be rated in gallons per hour at zero head, 1 m and 2 m, because delivered flow falls as lift rises; a rating at zero head alone overstates what reaches the thru-hull.ABYC H-22 (2005 edition), rating appendix
- ScienceIn laboratory tests the BoatUS Foundation commissioned from the University of Virginia's Department of Mechanical and Aerospace Engineering, all five test pumps ran 15 to 33 percent below their rated capacities, and flow fell further with corrugated hose and small thru-hull fittings. The page dates the work as pre-1990 and does not name the pumps.BoatUS Foundation, Bilge Pump System Tests
- ReviewPractical Sailor's October 2010 bench test measured the Johnson Ultima Bilge 1,250 GPH, claimed at 800 GPH with 3 ft of head, at 692 GPH with 4 ft of head at 13.6 V and 621 GPH at 12.2 V. The two Rule pumps in that test (the 1,500 GPH Model 02 and Rule-Mate 1500, not the 27SA) also fell short of their 1,200 GPH claims, at 1,029 and 973 GPH, and the magazine's bottom line was that both were outperformed by others. The models may have changed since 2010.Practical Sailor, Bottom Dwellers: Bilge Pumps II, October 2010
- Our pickRule Automatic Bilge Pump, 1100 GPH (model 27SA)1005 GPH (3804 L/h) at 3.3 ft (1 m); test voltage not stated
- Rule 1100 GPH size (Rule's standard pump manual)860 GPH (3255 L/h) at 3.35 ft, 13.6 V after a 10 hour break-in
- Johnson Pump Ultima Bilge 1250 GPH800 GPH (51 l/min) at 3 ft (0.9 m) of head, 13.6 V
- SEAFLO 11 Series 1100 GPH (SFBP1-G1100-11)806 GPH (3050 LPH) at 1 m, 12 V
Higher is better: more water reaches the thru-hull. These are each maker's own published figures, and no two come from the same test bench. Head points and voltages differ. Rule's 360-1100 manual quotes 3.3 ft (1 m) and does not state a test voltage. Rule's standard pump manual gives a lower 860 GPH for the same size, at 3.35 ft and 13.6 V. Johnson Pump quotes 3 ft (0.9 m), a little less lift than 1 m, at 13.6 V. SEAFLO quotes 1 m at 12 V.
Source: Rule Automatic Bilge Pump, 1100 GPH (model 27SA)Source: Rule 1100 GPH size (Rule's standard pump manual)Source: spxflow.comSource: seaflo.com
Rule
Rule's 360-1100 GPH manual, which covers the automatic models, gives 1005 GPH (3804 L/h) at 3.3 ft (1 m) and 825 GPH (3123 L/h) at 6.7 ft (2 m) for the 1100 GPH series; it does not state the test voltage. Rule's standard pump manual gives lower figures for the 1100 size: 860 GPH (3255 L/h) at 3.35 ft and 550 GPH (2081 L/h) at 6.7 ft, at 13.6 V after a 10 hour break-in.
Johnson Pump
Johnson Pump publishes 800 GPH (51 l/min) at 3 ft (0.9 m) of head for the Ultima Bilge 1250 GPH and 700 GPH (44 l/min) for the Ultima Bilge 1000 GPH, both at 13.6 V. Its product page and product bulletin give no figure at 2 m.
SEAFLO
SEAFLO publishes 806 GPH (3050 LPH) at 1 m and 506 GPH (1915 LPH) at 2 m for the 11 Series 1100 GPH pump (SFBP1-G1100-11) at 12 V.
Water level when it switches on and off
The Rule starts with about a third of the water in the bilge and stops with about a third as much left behind: 1.6 cm against 5 cm to start, 0.6 cm against 2 cm at stop (our arithmetic on the published figures). Less standing water between runs means less water to go sour and smell.
What backs this up (1)
- In the fieldWriting in Passagemaker in 2021, Peter Frederiksen says "any water that enters the bilge can breed smells and mildew" and that washing alone will not remove the stench of the sour water the bilge pump leaves behind; he advises taking out standing water first.Passagemaker, How to tame a smelly bilge (2021)
- Our pickRule Automatic Bilge Pump, 1100 GPH (model 27SA)5/8 in (1.6 cm)
- Johnson Pump Ultima Switch50 mm (2 in) fluid level, with a three second delay
- Johnson Pump Ultima Bilge 1250 GPH (integrated switch)Not published
Lower is better: the pump starts with less water standing in the bilge. Rule states its 5/8 in figure for its automatic pumps as a family, not for the 27SA alone. Those pumps check for water every 2 1/2 minutes, where Johnson's Ultima switch waits for water. The 2 in figure is for Johnson's separate Ultima Switch, which has a three second delay against water sloshing in the bilge. Johnson's Ultima Bilge page names an integrated Ultima field effect switch but gives no switching level, so that pump shows as Not published. SEAFLO is not compared on this point.
Source: xylem.comSource: ittflowtechnologies.comSource: spxflow.com
Rule
Rule states its automatic pumps activate at 5/8 in (1.6 cm) of water and drain down to 1/4 in (0.6 cm).
Johnson Pump
Johnson Pump's Ultima Bilge page names an integrated Ultima field effect switch and gives no switching levels. Johnson's page for its Ultima Switch states that it activates at a 50 mm (2 in) fluid level and deactivates at 20 mm (3/4 in), with a three second delay against water sloshing in the bilge.
Switching with no float
A float is a moving part that sits in the dirtiest water on the boat. The Rule has nothing in the bilge to lift, stick or foul; it decides by the load on its own impeller. The accounts below are about float switches in general, not about the SEAFLO pump.
What backs this up (3)
- ReviewPractical Sailor's 2010 installation advice says a pump's water sensor should resist fouling and that "common float switches should be in a housing" because otherwise they are more prone to fouling by debris.Practical Sailor, Rules of Thumb for Bilge Pump Installations, October 2010
- In the fieldCottage Life (Canada) warns that debris can stop a float switch from lifting to start the pump, or from dropping again to stop it, and advises lifting the float by hand to test it.Cottage Life, What to do if your bilge pump fails (October 2025)
- In the fieldOn The Tugnuts owners' forum in June 2019, a Ranger 31 owner reported a failed float sensor, and another owner blamed paint flakes from engine hoses: "These paint chips are very efficient at fouling the float." These are single owners' accounts.The Tugnuts forum, Failed Float Switch (2019)
Rule
Rule automatic pumps need no float switch: the pump turns on for about a second every 2 1/2 minutes, measures the load on the impeller, and keeps running until the water is removed.
SEAFLO
SEAFLO describes the 11 Series 1100 GPH as an all-in-one pump with a built-in magnetic float switch, which turns the pump on when the water level rises and off when the water is removed.
When a rival is the better fit
Johnson Pump lists the Ultima Bilge 1250 at 3 A on a 5 A fuse against the Rule 27SA's 3.7 A at 12 V (4.7 A at 13.6 V) on a 7.5 A fuse, and its Ultima switch waits for water instead of running a check every 2 1/2 minutes, so on a boat left on a mooring with no charger that pump, or Rule's own level-sensing Rule-Mate, is the reasonable choice.
Our pick
Rule Automatic Bilge Pump, 1100 GPH (model 27SA)

Rule’s page for this product About Rule and its publications
A fully submersible 12 V automatic pump that needs no float switch. It is the size that suits most 18 to 25 ft boats, and the same series covers 500 GPH to 4000 GPH for smaller and larger hulls.
- More water at a real lift: Rule publishes 1005 GPH (3804 L/h) at 3.3 ft (1 m) and 825 GPH (3123 L/h) at 6.7 ft (2 m) for the 1100 GPH series. Johnson Pump publishes 800 GPH at 3 ft (0.9 m) for its larger-rated Ultima Bilge 1250, and SEAFLO 806 GPH at 1 m for its 11 Series 1100. Source: xylem.com
- It starts sooner and leaves less behind: Rule states its automatic pumps activate at 5/8 in (1.6 cm) and drain down to 1/4 in (0.6 cm), where Johnson Pump's Ultima Switch activates at 50 mm (2 in) and stops at 20 mm (3/4 in), and a standard pump with a float switch lets water reach 2 in (5 cm). Source: xylem.com
- No float to buy, wire, jam or foul. The pump checks for water every 2 1/2 minutes by the load on its impeller and runs until the water is removed. Source: xylem.com
- Built for the bilge: ignition protection, a built-in thermal cut-off, back flow prevention on the 500-1100 models, a snap-lock strainer base that comes off for cleaning, and CE and ISO 8849 certification. Source: xylem.com
- A manual override lead (brown with a white stripe) lets a three-position panel switch run the pump on demand. Source: xylem.com
- Low current for the flow: 3.7 A at 12 V on a 7.5 A fuse, with a 24 V version (27SA-24) at 1.9 A on a 4.0 A fuse. Source: xylem.com
Published specifications (11)
- Model
- 27SA (12 V)27SA-24 (24 V)
- Rated capacity
- 1100 GPH (4164 LPH)
- Current draw
- 3.7 A at 12 V4.7 A at 13.6 V
- Fuse
- 7.5 A (12 V model)
- Hose diameter
- 1‑1/8 in (29 mm) or 1 in (25 mm)
- Height x width
- 4.7 in (120 mm) x 2.9 in (74 mm)
All other rows:Source: xylem.com
Part numbers to order by (2)
- Rule 1100 GPH automatic bilge pump, 12 V DC
- 27SA
- Rule 1100 GPH automatic bilge pump, 24 V DC
- 27SA-24
All 2 rows:Source: xylem.com
What size bilge pump do I need for my boat?
Pick the pump by the flow it delivers at your boat's discharge height, then fit the largest one that the bilge space, hose run and wiring will take. Boat length is only a shortcut for how much water a hull can collect and how high the pump has to lift it.
Our working recommendation, using Rule's range: under 18 ft, an 800 GPH automatic (20SA), or the 500 GPH 25SA where space or battery is tight. From 18 to 25 ft, an 1100 GPH automatic (27SA). From 25 to 32 ft, a 1500 GPH pump (51S or Rule-Mate RM1500A). From 32 to 45 ft, a 2000 GPH pump (53S or Rule-Mate RM2000A) in the main bilge and a 3700 GPH standard pump on its own float switch, mounted higher, as the backup. Above 45 ft, 3700 or 4000 GPH pumps (55S, 56S) and one pump for every compartment that can hold water.
These length bands are our recommendation, not a standard. The model capacities, hose sizes and fuse sizes in them are Rule's published figures.
- Measure the vertical distance from the pump to the highest point of the discharge hose (the thru-hull or the top of a loop). That is the head.
- Read the pump's published flow at that head: 3.3 ft (1 m) suits most open boats, 6.7 ft (2 m) is common on cruisers and sailboats.
- Choose the pump whose flow at that head, not at zero head, meets the size band above. If the hose run is long or has several bends, go up a size.
- Check the pump's height, width and hose size against the space: 800 and 1100 GPH Rule automatics are 2.9 in wide, 1500 and 2000 GPH models are 4.75 in wide.
- On any boat that stays in the water, add a second pump mounted higher on a separate switch and circuit.
Why does one guide say 500 GPH and another 2,500 GPH for a 20 ft boat?
Because no standard gives a number, and the guides are counting different things. Published advice for a 20 ft boat runs from about 500 GPH to 2,500 GPH. The 2005 edition of ABYC H-22 covers how an electric bilge pump system is rated, installed and controlled; it does not set a capacity by boat length.
Three things explain the spread. First, some figures are label ratings measured at zero head and some are what reaches the thru-hull. Second, some are for one pump and some are the total for a primary and a backup. Third, a small pump for rainwater and a large pump to buy time are both called a bilge pump.
The figures reconcile once flow is read at the installed head. On a 20 ft boat with about 3.3 ft of lift, Rule's 500 GPH pump delivers 470 GPH, its 800 delivers 790 GPH and its 1100 delivers 1005 GPH. A single 1100 GPH automatic therefore sits in the middle of the published range in delivered terms, and adding an 800 or 1100 GPH backup takes the installed total to about 1,900 to 2,200 GPH rated, which is where the high-end advice lands.
H-22 also lists what cuts installed capacity: the length of the discharge run, the number and radius of bends, rough hose walls, and restrictions such as check valves and thru-hulls. That is why two boats with the same pump can discharge different amounts.
How many GPH does a bilge pump really deliver at 3 ft and 6 ft of lift?
Less than the label, and the loss grows quickly with height. Rule publishes flow at zero head, 3.3 ft (1 m) and 6.7 ft (2 m) for each pump series, which are the three rating points ABYC H-22 calls for.
For the small pumps the table below shows that the 1100 GPH series keeps about 91% of its rating at 3.3 ft and 75% at 6.7 ft, while the 500 GPH series keeps 94% and 54%. The percentages are our arithmetic on Rule's figures. A small pump on a tall lift loses the most.
Rule's separate manual for standard pumps from 360 to 4000 GPH lists lower open-flow outputs for the 360 to 1100 sizes (for example 860 GPH at 3.35 ft and 550 GPH at 6.7 ft for the 1100, at 13.6 V). The figures in the table above are from the 360-1100 GPH manual, which also covers the automatic models.
| Series | Flow at 0 ft | Flow at 3.3 ft (1 m) | Flow at 6.7 ft (2 m) | Maximum head |
|---|---|---|---|---|
| 360 GPH1,360 L/h | 417.3 GPH1,580 L/h | 308 GPH1,170 L/h | 150 GPH568 L/h | 12 ft (3.7 m) |
| 500 GPH1,890 L/h | 572 GPH2,170 L/h | 470 GPH1,780 L/h | 270 GPH1,020 L/h | 11 ft (3.4 m) |
| 800 GPH3,030 L/h | 1045 GPH3,960 L/h | 790 GPH2,990 L/h | 575 GPH2,180 L/h | 12 ft (3.7 m) |
| 1100 GPH4,160 L/h | 1116 GPH4,220 L/h | 1005 GPH3,800 L/h | 825 GPH3,120 L/h | 10 ft (3 m) |
How much do the larger 1500 to 4000 GPH pumps deliver at head?
A 2000 GPH Rule pump delivers 1620 GPH at 3.35 ft and 1300 GPH at 6.7 ft; a 3700 delivers 2900 GPH and 2450 GPH. Rule notes that these outputs are measured after a 10 hour break-in period at 13.6 V for 12 V models, so expect less on a battery that is not being charged.
The 1500 GPH pump drops to 680 GPH at 6.7 ft, less than half its rating. On a boat with a tall lift the 2000 GPH model is the better choice even where 1500 GPH looks sufficient on paper.
| Rated flow | Output at 0 ft | Output at 3.35 ft (1 m) | Output at 6.7 ft (2 m) |
|---|---|---|---|
| 1500 GPH5,680 L/h | 1500 GPH5,680 L/h | 1200 GPH4,540 L/h | 680 GPH2,570 L/h |
| 2000 GPH7,570 L/h | 2000 GPH7,570 L/h | 1620 GPH6,130 L/h | 1300 GPH4,920 L/h |
| 3700 GPH14,000 L/h | 3700 GPH14,000 L/h | 2900 GPH10,980 L/h | 2450 GPH9,270 L/h |
| 4000 GPH15,140 L/h | 4000 GPH15,140 L/h | 3527 GPH13,350 L/h | 2952 GPH11,170 L/h |
Automatic or manual bilge pump: which should I buy?
Buy an automatic pump for any boat that is left in the water or left unattended, and wire it with a manual override. A manual (standard, non-automatic) electric pump only runs when someone flips the switch, which suits a trailered boat that is bailed at the ramp or a second pump controlled by its own float switch.
There are three ways to make a pump automatic. A standard pump with a separate float switch is the traditional arrangement; Rule's float switches cover pumps from 360 GPH up to 4000 GPH. A Rule Automatic pump has no float: it checks for water every 2 1/2 minutes by running for a second. A level-sensing pump, such as the Rule-Mate or the LoPro LP900S, switches on when water reaches a set height and does not cycle while the bilge is dry.
The difference matters on a mooring with no charger. A checking pump runs briefly every 2 1/2 minutes whether or not there is water; a level-sensing pump or a float switch stays off until water arrives. The checking pump, in return, starts at a lower water level and leaves less behind.
ABYC H-22 (2005 edition) requires a pump with automatic controls to have a readily accessible manual switch and a visual indication that power is being supplied to it. Rule's automatic pumps have two positive leads for this: brown for automatic and brown with a white stripe for manual override.
What hose, wire and fuse does a bilge pump need?
Use the hose size the pump outlet is made for, in smooth-bore flexible hose, and the fuse size the maker lists for that model. In Rule's automatic pump model table, the 500 and 800 GPH pumps take 3/4 in hose, the 1100 takes 1‑1/8 in or 1 in, the 1500 and 2000 take 1‑1/8 in, the 3700 takes 1‑1/2 in and the 4000 takes 2 in.
Rule's fuse sizes for 12 V automatic pumps are 4 A for the 500 GPH, 7.5 A for the 800 and 1100, 10 A for the 1500, 15 A for the 2000 and 25 A for the 3700 and 4000. The fuse protects the pump wiring, so do not fit a larger one.
Rule supplies its 360-1100 GPH pumps with tinned 16 gauge wire and gives the table below for extending it. The length is the full circuit: positive to pump and back to ground. Keep every connection above the highest water level and join wires with butt connectors and marine sealant.
Mount the thru-hull discharge at least 8 in (20.3 cm) above the heeled waterline. Rule's instructions allow it below that line only with a seacock and a vented loop or other means to prevent siphoning. A check valve may be used only to stop an automatic pump cycling on back flow; it must not be used to prevent siphoning or in a shared discharge manifold.
| Total wire length (positive to pump to ground) | Wire size |
|---|---|
| 0-6 ft0.0-1.8 m | 16 AWG (1.5 mm2) |
| 6-10 ft1.8-3.0 m | 14 AWG (2.5 mm2) |
| 10-15 ft3.0-4.6 m | 12 AWG (4 mm2) |
| 15-30 ft4.6-9.1 m | 10 AWG (6 mm2) |
| 30-40 ft9.1-12.2 m | 8 AWG (10 mm2) |
Do I need a backup bilge pump and a high-water alarm?
Fit a second pump on any boat kept afloat, and an alarm on any boat with a cabin. Rule's installation instructions state that on boats with an enclosed accommodation compartment an audible alarm shall be installed to indicate that bilge water is approaching the maximum bilge water level.
Mount the backup pump higher than the primary so it stays clean and dry in normal use, give it its own float switch and its own fused circuit, and choose a larger capacity than the primary. Rule's standard pump model table lists the Super Switch (37A) and Rule-A-Matic Plus (40A) float switches for its 3700 and 4000 GPH standard pumps; both are rated for pumps drawing up to 20 amps, where the basic Rule-A-Matic (35A) is rated to 14 amps.
If two pumps share one thru-hull, the system must be designed so that one pump cannot back feed the other and both can run together without losing capacity. Separate discharges are simpler.
If your boat or use is different

For skiffs, jon boats and other open boats under 18 ft
Rule Automatic Bilge Pump, 800 GPH (model 20SA)
The same footprint as the 1100 on 3/4 in hose. Rule publishes 790 GPH at 3.3 ft of head for the 800 GPH series. Where battery capacity is small, the 500 GPH 25SA draws 2.1 A at 12 V on a 4 A fuse.
Specifications (5)
- Rated capacity
- 800 GPH (3028 LPH)
- Current draw and fuse
- 3.4 A at 12 V7.5 A fuse
- Hose diameter
- 3/4 in (19 mm)
- Height x width
- 4.7 in (120 mm) x 2.9 in (74 mm)
All other rows:Source: xylem.com

For shallow or tight bilges where a round pump will not fit
Rule LoPro LP900S
A low-profile 900 GPH pump that mounts horizontally or vertically with a rotating discharge body. It has two automatic modes: level sensing at a selectable 2 in (5 cm) or 1.3 in (3.25 cm), or a water check every 2.5 minutes. The LP900D version has no sensor and runs from a float or panel switch.
Specifications (3)
- Flow rate
- 900 GPH (3407 LPH)
- Certification
- CE, ISO 8849 and ISO 8846
All other rows:Source: xylem.com

For cruisers and sailboats of roughly 25 to 45 ft that want level sensing instead of a timed check
Rule-Mate RM1500A and RM2000A
Automatic pumps that turn on when water reaches about 2‑3/4 in (70 mm) and shut off at about 5/8 in (16 mm), so they do not cycle in a dry bilge. If debris covers the sensor the pump falls back to checking for water every 2.5 minutes. Use the RM1500A up to about 32 ft and the RM2000A above that.
Specifications (5)
- Rated capacity
- RM1500A 1500 GPH (5678 LPH)RM2000A 2000 GPH (7571 LPH)
- Output at 3.35 ft / 6.7 ft head
- RM1500A 1200 / 680 GPHRM2000A 1620 / 1300 GPH
- Current draw at 12 V
- RM1500A 4.8 ARM2000A 8.4 A
- Fuse
- RM1500A 10 ARM2000A 15 A
- 24 V version
- RM2000A-24, 4.0 A at 24 V, 7.5 A fuse
All 5 rows:Source: amp.xylem.com

For main bilge pump on a 32 to 45 ft boat, with no float switch
Rule Automatic Bilge Pump, 2000 GPH (model 53S)
The 2000 GPH automatic on 1‑1/8 in hose. For boats of 25 to 32 ft the 1500 GPH 51S has the same 7.75 in x 4.75 in body and a 10 A fuse.
Specifications (4)
- Rated capacity
- 2000 GPH (7571 LPH)
- Current draw and fuse
- 8.4 A at 12 V15 A fuse
- Hose diameter
- 1‑1/8 in (29 mm)
- Height x width
- 7.75 in (197 mm) x 4.75 in (121 mm)
All 4 rows:Source: xylem.com

For high-capacity backup pump, mounted above the primary on its own float switch
Rule 3700 GPH Standard Bilge Pump (models 13A, 14A) with Super Switch 37A
A switch-operated pump that stays dry until it is needed. Rule publishes 2900 GPH at 3.35 ft and 2450 GPH at 6.7 ft for the 3700 series. Standard pumps carry a limited 3-year warranty and the Super Switch a 5-year warranty.
Specifications (5)
- Rated capacity
- 3700 GPH (14010 LPH)
- Fuse
- 25 A (12 V)
- Hose diameter
- 1‑1/2 in (38 mm)
All other rows:Source: xylem.com

For trailered boats that only need a pump on a helm switch
Rule Standard Bilge Pump, 500 to 1100 GPH (models 25DA, 20DA, 27DA)
The non-automatic versions of the same pumps, run from a panel switch or paired with a float switch later. Rule states they have a vented impeller housing to prevent airlock and a limited 3-year warranty.
Specifications (3)
- Capacities
- 500 GPH (25DA), 800 GPH (20DA), 1100 GPH (27DA)
- Current draw at 12 V
- 1.6 A, 3.4 A, 3.7 A
All other rows:Source: xylem.com

For removing the last water that a submersible pump leaves behind
Rule Dry Bilge Pump DB412
A self-priming pump that mounts out of the bilge and draws through a 3/4 in hose run to the deepest point. It is a low-volume pump for a dry bilge, to be used alongside a main bilge pump and not in place of one.
Specifications (2)
- Flow
- Up to 4.0 US gpm (15 lpm)
- Suction lift
- 9.5 ft (3 m)
All 2 rows:Source: xylem.com
How the options compare
| Model | Automatic control | Rated flow | Published flow at about 1 m of head | Outlet | Current draw | Fuse |
|---|---|---|---|---|---|---|
| Rule 27SARuleOur pickSource | Checks for water every 2 1/2 minutes | 1100 GPH | 1005 GPH at 3.3 ft | 1-1/8 in or 1 in | 3.7 A at 12 V | 7.5 A |
| Rule 20SARuleRecommended brandSource | Checks for water every 2 1/2 minutes | 800 GPH | 790 GPH at 3.3 ft | 3/4 in | 3.4 A at 12 V | 7.5 A |
| Rule 25SARuleRecommended brandSource | Checks for water every 2 1/2 minutes | 500 GPH | 470 GPH at 3.3 ft | 3/4 in | 2.1 A at 12 V | 4 A |
| Johnson Pump Ultima Bilge 1250 GPHJohnson Pump (SPX FLOW)Source | Integrated switch | 1250 GPH | 800 GPH at 3 ft (0.9 m), 13.6 V | 1-1/8 in and 1-1/4 in | 3 A | 5 A |
| Johnson Pump Ultima Bilge 1000 GPHJohnson Pump (SPX FLOW)Source | Integrated switch | 1000 GPH | 700 GPH at 3 ft (0.9 m), 13.6 V | 3/4 in | 3.2 A | 5 A |
| SEAFLO 11 Series 1100 GPH (SFBP1-G1100-11)SEAFLOSource | Built-in magnetic float switch | 1100 GPH | 806 GPH at 1 m (12 V) | 1-1/8 in (29 mm) | 3.0 A | Not stated; 5.0 A maximum draw |
| SEAFLO 11 Series 750 GPH (SFBP1-G750-11)SEAFLOSource | Built-in magnetic float switch | 750 GPH | 504 GPH at 1 m (12 V) | 3/4 in (19 mm) | 3.0 A | Not stated; 5.0 A maximum draw |
Questions people ask next
Rule vs Johnson Pump vs SEAFLO: which automatic bilge pump is better?
For an 18 to 25 ft (5.5 to 7.6 m) boat we pick the Rule 27SA. Rule publishes 1005 GPH (3804 L/h) at 3.3 ft (1 m) for its 1100 GPH pumps; Johnson Pump publishes 800 GPH at 3 ft (0.9 m) for the Ultima Bilge 1250 and SEAFLO 806 GPH at 1 m for the 11 Series 1100. Rule's own standard pump manual gives a lower 860 GPH at 13.6 V, which is still ahead. The Rule starts at 5/8 in (1.6 cm) of water with no float, where Johnson's Ultima Switch starts at 2 in (50 mm) and SEAFLO uses a magnetic float. An independent Practical Sailor bench test in 2010 measured the Ultima 1250 at 692 GPH with 4 ft of head at 13.6 V, below its 800 GPH claim; it did not test the 27SA. Choose the Johnson if a lower current draw (3 A against 3.7 A) and no check cycle in a dry bilge matter more than flow.
What size bilge pump do I need for a 20 ft boat?
Fit an 1100 GPH automatic pump as the primary. Rule's 1100 GPH series delivers 1005 GPH at 3.3 ft of lift and 825 GPH at 6.7 ft, on a 7.5 A fuse and 1‑1/8 in or 1 in hose. If the boat stays in the water, add a second pump mounted higher on its own switch.
What size bilge pump for a 16 ft boat?
An 800 GPH automatic such as the Rule 20SA. Rule's 360-1100 GPH manual, which covers the automatic models, gives 790 GPH at 3.3 ft of head for the 800 GPH series and 470 GPH for the 500 GPH series. In Rule's automatic pump model table the 20SA takes 3/4 in hose and draws 3.4 A at 12 V; the 500 GPH 25SA draws 2.1 A, is the minimum we would fit, and suits a small battery.
What size bilge pump for a 40 ft boat?
A 2000 GPH pump in the main bilge (Rule 53S or Rule-Mate RM2000A, 1620 GPH at 3.35 ft and 1300 GPH at 6.7 ft per Rule's Rule-Mate 1500-2000 GPH user guide) and a 3700 GPH standard pump mounted higher on its own float switch as the backup, with a high-water alarm. Give every separate compartment that can hold water its own pump.
Is there a legal or ABYC minimum bilge pump size for a recreational boat?
ABYC H-22 (2005 edition) does not set a capacity by boat length. It covers how electric bilge pump systems are rated, installed and controlled, and its own text states that ABYC standards are advisory and voluntary. It does require an alarm on boats with an enclosed accommodation compartment and a manual switch for any automatic pump.
How does an automatic bilge pump work without a float switch?
A Rule Automatic pump turns itself on for about a second every 2 1/2 minutes and measures the load on the impeller. If there is water it keeps running until the water is removed, then goes back to checking. Rule-Mate pumps instead sense water level, switching on at about 2‑3/4 in and off at about 5/8 in.
Can a bilge pump keep a boat with a hole in it afloat?
No. Rule states that its bilge pumps are not intended for damage control or flooding from hull damage; they are for normal amounts of water in an intact boat from spray, rain, seepage and spillage. A larger pump buys time to find a leak and reach help, which is the reason to fit the biggest one the boat can take.
Should I put a check valve in the bilge pump hose?
Only if an automatic pump keeps cycling because water runs back down the hose. Rule's instructions, which follow ABYC H-22, say a check valve must not be used to prevent siphoning or in a manifold shared by several pumps. Rule lists back flow prevention as a built-in feature of its 500-1100 GPH automatic pumps.
Can a Rule bilge pump run dry?
For a limited time. Xylem states that its submersible bilge pumps can be run dry for up to two hours, and that pump life is extended by avoiding dry running.
Is the Rule automatic bilge pump made in 24 V, and which standards does it meet outside the US?
Two sizes come in 24 V: the 1100 GPH 27SA-24 (1.9 A at 24 V, 4.0 A fuse) and the 500 GPH 25SA-24 (1 A at 24 V, 3 A fuse). Rule lists CE and ISO 8849 certification for its automatic pumps, and its manual places them in bilge pumping systems as defined in ISO 15083, for small craft up to 24 m hull length. The manual is printed in English, French, German, Italian, Dutch, Swedish and Spanish. The Rule documents we read do not mention an Australian or New Zealand standard (AS/NZS) or AMSA. Rule rates flow in US gallons per hour and gives litres per hour beside it, for example 1100 GPH (4164 LPH).
Sources
This comparison relies on 22 documents, each read on the date the facts were verified. All sources in the library
List of sources (22)
- RuleRule Automatic Bilge Pumps: features and model numbers (Xylem)
- RuleRule Standard Bilge Pumps: features, warranty and model numbers (Xylem)
- RuleRule LoPro bilge pumps (Xylem)
- RuleRule Bilge Pump Float Switches (Xylem)
- RuleBilge Water Pumping application guide (Xylem)
- RuleRule 360-1100 GPH Bilge Pump instruction manual: wiring, fusing, plumbing and flow at head
- RuleRule Standard Bilge Pump instruction manual: open flow output at head, 360-4000 GPH
- RuleRule Automatic Bilge Pumps model number table
- RuleRule Standard Bilge Pumps model number table
- RuleRule Dry Bilge Pump DB412 instruction manual
- Public.Resource.OrgABYC H-22, Electric Bilge Pump Systems, July 2005 edition (public copy of the edition incorporated by reference into US regulation)
- Johnson PumpJohnson Pump Ultima Bilge automatic submersible bilge pumps (SPX FLOW)
- SEAFLOSEAFLO 11 Series 750 GPH automatic bilge pump
- Johnson PumpJohnson Pump Ultima Bilge product bulletin: flow at 3 ft head, current, fuse, sizes (SPX FLOW, 2025)
- Johnson PumpJohnson Pump bilge pump switches: Ultima Switch activation and deactivation levels (SPX FLOW)
- SEAFLOSEAFLO 11 Series 1100 GPH automatic bilge pump: flow at head table, current and warranty
- Practical SailorPractical Sailor, Bottom Dwellers: Bilge Pumps II, bench test of pumps of 1,500 GPH and below (October 2010)
- BoatUS FoundationBoatUS Foundation, Bilge Pump System Tests (University of Virginia laboratory tests)
- PassageMakerPassagemaker, How to tame a smelly bilge (2021)
- Cottage LifeCottage Life, What to do if your bilge pump fails (October 2025)
- TugNuts forumThe Tugnuts owners' forum, Failed Float Switch thread (June 2019)
- RuleRule-Mate RM1500A-RM2000A user guide (Xylem)