Skip to content
Best for Boats

Best livewell pump and best washdown pump: how to size each, and aerator vs washdown

Pumps & plumbingFacts verified Page updated

The short answer

The best livewell (live bait tank, aerator) pump is the Rule Livewell Pump Series, because Rule publishes the flow that reaches the tank and it is higher than the rival figure.

The 603 delivers 600 GPH (2271 LPH) at 3.3 ft (1 m) of lift on 4.1 A at 12 V, where Attwood rates its Tsunami Mk2 T800 at 2142 LPH at 1 m and Johnson Pump's Aqua O2 page gives open flow only. The 601 (500 GPH, 1892 LPH) suits a skiff, and the 605 (1100 GPH, 4163 LPH) or the 1600 GPH (6056 LPH) Rule 209 suits large offshore wells. The best washdown (deck wash) pump is the Jabsco HotShot HD4 kit (4 GPM / 15 LPM, 60 psi / 4.1 bar, 25 ft / 7.6 m hose coil included), which self-primes from up to 8 ft (2.4 m) against 6 ft (1.82 m) for the Shurflo Pro Blaster II and carries a 3 year warranty against 2 years. The two pumps are different machines: size the livewell pump by flow per hour delivered at the tank, and the washdown pump by flow per minute and pressure.

The publisher of this comparison has a commercial relationship with the brand it recommends. Every reason is shown with its source so you can check it. How picks are made

Key facts

  1. Rule 601, 603 and 605 livewell pumps are rated 500, 800 and 1100 GPH (1892, 3028 and 4163 LPH) at open flow and deliver 425, 600 and 825 GPH (1609, 2271 and 3123 LPH) at 3.3 ft (1 m) of head. Source: xylem.com

  2. At 12 V DC the Rule 601, 603 and 605 draw 3.0 A, 4.1 A and 4.7 A, and take a 5 A, 7.5 A and 7.5 A fuse. Rule lists all nine models at 12 V DC only. Source: xylem.com

  3. Rule livewell pumps are not self-priming and must be mounted below the waterline. Source: xylem.com

More key facts (3)
  1. Jabsco HotShot washdown pumps run from 3 GPM (11 LPM) at 50 psi (3.4 bar) (HotShot 3) to 6 GPM (23 LPM) at 70 psi (4.8 bar) (HotShot HD6), with maximum current from 7.5 A to 19.2 A at 12 V. The HD4 and HD6 are also made in 24 V versions. Source: xylem.com

  2. Every Rule 601, 603 and 605 has a second 1/2 in NPT female port so a washdown pump can be fed from the same thru-hull. Source: xylem.com

  3. Livewell oxygen should be 5 parts per million or higher, according to the Keeping Bass Alive guidebook written by B.A.S.S., U.S. Geological Survey and Texas Parks and Wildlife authors. Source: dnr.maryland.gov

Why Rule over Johnson Pump, Attwood and Shurflo

For the livewell (live bait tank), Rule publishes the flow at 3.3 ft (1 m) of lift for every model, and at the 500 and 800 GPH sizes it is higher than Attwood's published 1 m figure; Johnson Pump's Aqua O2 page gives open flow only. For washdown (deck wash), the Jabsco HotShot HD4 is rated to self-prime from up to 8 ft (2.4 m) against 6 ft (1.82 m) for the Shurflo Pro Blaster II, and Jabsco's HD models carry a 3 year warranty against 2 years. Livewell pumps are compared only with livewell pumps here, and washdown pumps only with washdown pumps.

Livewell: flow delivered at 3.3 ft (1 m) of lift

The number on the box is open flow, but the pump has to lift water to the tank. At 12 V and 1 m of lift, Rule rates its 800 GPH pump at 2271 LPH against 2142 LPH for Attwood's T800, and its 500 GPH pump at 1609 LPH against 1182 LPH for the T500. With the Aqua O2 the buyer cannot size to the tank from the maker's page. These are each maker's own figures, not one test bench.

What backs this up (2)
  • ScienceABYC H-22 (2005) requires electric bilge pumps to be rated "at heads of zero, one meter, and two meters", and notes that installed discharge capacity is reduced by hose length, bends, rough interior surfaces and narrow fittings. H-22 is the bilge pump standard; the same lift losses apply to any impeller pump that lifts water to a tank.ABYC H-22, Electric Bilge Pump Systems (2005), appendix Ap.22.1
  • ReviewBoating magazine's BoatingLAB (2012) tested livewell pumps on 12.5 V, mostly at about 30 in (0.76 m) of head. Measured flow against the box rating ranged from 3% below at 30 in (Attwood Tsunami T1200) to 29% above the no-head rating (Johnson Cartridge Aerator 750), so the box rating alone did not predict delivered flow in either direction. This evidence is mixed: Rule pumps were not in that test, and the models have changed since.Boating magazine, BoatingLAB livewell and raw-water pump test, 2012
Livewell pump flow at 1 m (3.3 ft) of lift, 12 V, 800 GPH size
  • Our pickRule 6032271 LPH (600 GPH) at 3.3 ft (1 m) of head, 12 V nominal
  • Attwood Tsunami Mk2 T8002142 LPH at 1 m at 12.0 V (ISO)
  • Johnson Pump Aqua O2 800 GPHNot published (open flow only)

Higher is better: more water reaches the tank. Both figures are the makers' own ratings at 1 m and 12 V, not one test bench. Rule tested with fresh water at 12 V nominal; Attwood's figure is its ISO rating at 12.0 V. Attwood's other figure (498 GPH at 3.3 ft) is at 13.6 V, so it is left out here because the voltage differs. Johnson Pump's Aqua O2 page gives open flow only (800 GPH at 12 V), no flow at any head.

Source: xylem.comSource: docs.navico.comSource: ittflowtechnologies.com

  • Rule

    Rule publishes flow at 3.3 ft (1 m) of head for every livewell model, tested at 12 V nominal with fresh water: 425 GPH (1609 LPH) for the 500 GPH 601, 600 GPH (2271 LPH) for the 800 GPH 603 and 825 GPH (3123 LPH) for the 1100 GPH 605.

    Source: xylem.com

  • Attwood

    Attwood publishes two sets of figures for the Tsunami Mk2. T800: 498 GPH at 3.3 ft of head at 13.6 V (ABYC) and 2142 LPH at 1 m at 12.0 V (ISO). T500: 319 GPH at 3.3 ft at 13.6 V and 1182 LPH at 1 m at 12.0 V.

    Source: docs.navico.com

  • Johnson Pump

    Johnson Pump's Aqua O2 product page lists open flow only (500 GPH and 800 GPH at 12 V). It states no flow figure at any head, and it links no manual.

    Source: ittflowtechnologies.com

Washdown: how high above the water the pump can sit

A washdown pump is mounted in a dry place above the waterline, often high in a console or under a leaning post. On the two makers' ratings, the HD4 can sit 2 ft (about 0.6 m) higher above the water it draws from and still prime itself, by our arithmetic. That gives more choice of mounting place on a boat with a deep hull.

What backs this up (3)
  • ScienceABYC H-22 asks that positive or semi-positive displacement pumps (diaphragm pumps are this type) "also be rated at the maximum suction in feet (meters)". Suction lift is a rated property of the pump, not of the installation.ABYC H-22, Electric Bilge Pump Systems (2005), appendix Ap.22.2
  • In the fieldMarine Depot, an Australian chandlery, tells buyers that most 12 V diaphragm washdown pumps are self-priming only "to a specified lift height", typically 1 to 3 m, so the lift must be checked against the mounting place.Marine Depot (Australia), washdown pump buying guide
  • ReviewPractical Sailor's washdown pump test (2011, updated 2020) found that self-priming is not a given: one of the eight pumps, the Groco C-60, was unable to self-prime and had to be primed by the testers. Neither the HotShot nor the Pro Blaster II was in that test.Practical Sailor, Deck Washdown Pumps for Boats
Washdown pump dry self-prime height
  • Our pickJabsco HotShot HD4 kit (Q401J-118N-4A)Up to 8 ft (2.4 m) dry
  • Shurflo Pro Blaster II Deluxe 4.0 (4248-153)6 feet (1.82 m) dry prime

Higher is better: the pump can be mounted higher above the water it draws from and still prime itself. Both are the makers' published ratings for pumps of the same 4 GPM, 60 psi class, not one test bench. The Jabsco HD4 is this comparison's washdown pick (the Rule series is its livewell pick). Both makers say the pump can run dry.

Source: xylem.comSource: pentair.com

  • Rule

    Xylem rates the Jabsco HotShot HD4 kit (Q401J-118N-4A) to self-prime from up to 8 ft (2.4 m) dry, and states that it can run dry without damage.

    Source: xylem.com

  • Shurflo

    Shurflo rates the Pro Blaster II Deluxe 4.0 (4248-153) at a 6 feet (1.82 m) dry prime, and its run-dry rating is "Yes".

    Source: pentair.com

Washdown: warranty

A washdown pump works at high pressure, so its diaphragm, valves and pressure switch are the parts that wear. The Jabsco HD buyer gets one more year of cover on them than the Pro Blaster II buyer, on the makers' published terms.

What backs this up (1)
  • ReviewPractical Sailor rated the earlier Shurflo ProBlaster "Recommended" and noted its two-year warranty, adding: "we'd like to see it backed with the three-year warranty prevalent among the rest of our test group". The Jabsco pump in that test (Par-Max 7.0) had a three-year warranty. The test is from 2011, updated 2020, and covers earlier models.Practical Sailor, Deck Washdown Pumps for Boats
  • Rule

    Xylem's limited warranty for Jabsco HD washdown models is 3 years.

    Source: xylem.com

  • Shurflo

    Shurflo's marine catalog lists a 2 Year Warranty for the Pro Blaster II washdown pumps.

    Source: pentair.com

Livewell: second port for a washdown pump on every model

On a boat where the livewell pump goes straight through the transom or the bottom, a Rule lets the livewell pump and the washdown pump share one hole in the hull. Every fitting below the waterline is one more seal, hose and clamp to inspect.

What backs this up (2)
  • In the fieldBoatUS's review of its insurance claim files found that 69% of sinkings happened at the dock or mooring, and 39% of those when "some small part gives up the fight with water due to wear, tear and corrosion". Its advice is to inspect all below-waterline fittings, hoses and clamps each season.BoatUS claim files, reported by Sail-World, 2014
  • In the fieldOn the iBoats forum (2005), the owner of a 1989 20 ft (6.1 m) Grady-White asked how to feed a livewell pump and a washdown pump from one thru-hull; another owner described one transom thru-hull feeding two pumps, one for washdown and one for the aerator.iBoats forum owner thread, Livewell/Washdown Install Question
  • Rule

    Every Rule 601, 603 and 605, including the thru-hull models, is fitted with an additional 1/2 in NPT female port and hex plug, so a washdown pump can be added without another thru-hull fitting.

    Source: xylem.com

  • Johnson Pump

    Johnson Pump lists the Aqua O2 twin port on its seacock models (10-13649-01 and 10-13650-01). The page does not list a twin port for its thru-hull models (10-13642-01 and 10-13643-01).

    Source: ittflowtechnologies.com

Washdown: top pressure and flow in the range

For anchor chain and fish box work, the Jabsco range goes to 70 psi and 6 GPM, which the Pro Blaster II list does not reach. At the same 5 GPM flow, the HD5 shuts off at 70 psi (4.8 bar) against 60 psi (4.1 bar) for the Ultimate 5.0, on the makers' figures.

What backs this up (1)
  • In the fieldMarine Depot, an Australian chandlery, gives 40 to 60 PSI and 10 to 15 LPM as a practical range for deck wash on boats up to about 8 m, and says dedicated anchor wash systems "benefit from 60-80 PSI or more" to shift mud brought up from the seabed.Marine Depot (Australia), washdown pump buying guide
  • Rule

    The Jabsco HotShot range runs from 3 GPM (11 LPM) at 50 psi (3.4 bar) to 6 GPM (23 LPM) at 70 psi (4.8 bar). The HD5 (5 GPM, 19 LPM) and HD6 (6 GPM, 23 LPM) shut off at 70 psi (4.8 bar).

    Source: xylem.com

  • Shurflo

    Shurflo lists the Pro Blaster II at 4.0 GPM (15.1 LPM) and 5.0 GPM (18.9 LPM), both with a 60 PSI (4.1 bar) shut-off.

    Source: pentair.com

When a rival is the better fit

Attwood and Johnson Pump publish lower current in the 800 GPH class (Attwood T800 2.5 A at 1 m and 12.0 V, Johnson Aqua O2 800 3.7 A at 12 V, against 4.1 A for the Rule 603), Johnson Pump gives a limited 3 year warranty against Rule's 1 year, Attwood rates its T1200 above the Rule 605 at 1 m and 12 V (3282 LPH against 3123 LPH), and Attwood lists CE, RCM and UKCA approvals that Rule's livewell manual and flyer do not state. In washdown, the Shurflo Pro Blaster II draws less current at the same rating (10 A against 11.5 A at 4 GPM and 60 psi).

Each maker’s line is what that maker publishes on its own site, linked beside it. The reasoning beside each pair is ours. The backing under it comes from standards, independent tests, published reviews and people who use the product.

Our pick

Rule Livewell Pump Series (601, 603 and 605)

A 12 V livewell and baitwell pump in three flows (500, 800 and 1100 GPH) and three inlet styles, with a motor cartridge that twists out by hand. The 603 (800 GPH) is the size to start from; step down to the 601 for a small well or up to the 605 for a large one.

  • Xylem publishes the flow at 3.3 ft (1 m) of head as well as open flow: 425, 600 and 825 GPH (1609, 2271 and 3123 LPH). The pump can be sized to what actually reaches the tank. Source: xylem.com
  • Every model, thru-hull and seacock alike, has a second 1/2 in NPT female port with a hex plug, so a washdown pump can share the thru-hull. That is one less hole below the waterline. Source: xylem.com
  • The motor cartridge comes out with one hand (press the release button, twist counterclockwise, pull up), leaving the housing, thru-hull fitting and hose in place. The impeller can be inspected and cleared the same way. Source: xylem.com
  • Xylem states that the pump can withstand the pressures of high-speed water intake scoops, and lists advanced anti-airlock protection among its features. Source: xylem.com
  • Nine models cover angled thru-hull, straight thru-hull and seacock installations in each of the three flows, and all are supplied with threaded nylon hose barb attachments. Source: xylem.com
  • Xylem states that its pumps are designed to meet the ABYC standards for the current aquatic invasive species (AIS) decontamination procedure, including low-pressure water at 120 F (about 49 C) for 130 seconds. Source: xylem.com
Published specifications (12)
Open flow
500 GPH (601), 800 GPH (603), 1100 GPH (605)
Flow at 3.3 ft (1 m) head
425 GPH, 600 GPH, 825 GPH
Voltage
12 V DC
Source: xylem.com
Amp draw at 12 V DC
3.0 A, 4.1 A, 4.7 A
Source: xylem.com
Required fuse
5 A, 7.5 A, 7.5 A
Inlet styles
C angled thru-hull, STC straight thru-hull, FC straight seacock (3/4 in NPT)
Source: xylem.com
Discharge hose barb
3/4 in (601, 603), 1 1/8 in (605)
Source: xylem.com
Second port
1/2 in NPT female, plugged, for a washdown pump
Mounting hole
1 in (25 mm), below the waterline
Replacement motor cartridges
65DR (500 GPH), 66DR (800 GPH), 67DR (1100 GPH)
Maintenance interval
Inspect the impeller every 6 months
Warranty
1 year from date of manufacture

All other rows:Source: xylem.com

Part numbers to order by (8)
601 series, 500 GPH, straight seacock (FC), 12 V
601FC
603 series, 800 GPH, straight seacock (FC), 12 V
603FC
605 series, 1100 GPH, straight seacock (FC), 12 V
605FC
601 series, 500 GPH, straight thru-hull (STC), 12 V
601STC
603 series, 800 GPH, straight thru-hull (STC), 12 V
603STC
605 series, 1100 GPH, straight thru-hull (STC), 12 V
605STC
601 series, 500 GPH, angled thru-hull (C), 12 V
601C
603 series, 800 GPH, angled thru-hull (C), 12 V
603C

All 8 rows:Source: xylem.com

What is the difference between a livewell (aerator) pump and a washdown pump?

A livewell or aerator pump moves a large volume of water at almost no pressure; a washdown pump moves a small volume at high pressure. They are not interchangeable, and most fishing boats need one of each.

A Rule livewell pump sits below the waterline on a thru-hull or seacock, because it cannot prime itself. It is rated in gallons per hour (500 to 1100 GPH in the cartridge series).

A Jabsco HotShot washdown pump is a multi-chamber diaphragm pump mounted in a dry spot above the waterline. It primes itself, can run dry without damage, and has a sealed pressure switch that starts it when you squeeze the nozzle and stops it at the shut-off pressure (50 to 70 psi). It is rated in gallons per minute, and Xylem rates it for intermittent duty only.

For scale: the 4 GPM HotShot HD4 moves 240 gallons per hour (4 x 60, simple arithmetic), less than half the open flow of the smallest Rule livewell pump, but at 60 psi.

Livewell pump vs washdown pump, from Xylem's Rule and Jabsco documentation
Rule Livewell Pump SeriesJabsco HotShot washdown pumps
Pump typeImpeller pump, replaceable motor cartridge3, 4 or 5 chamber diaphragm
Rated inGPH: 500, 800, 1100GPM: 3, 4, 5, 6
PressureNo pressure rating; flow falls with head (800 GPH becomes 600 GPH at 3.3 ft)No pressure rating; flow falls with head (3,030 L/h becomes 2,270 L/h at 1.0 m)50, 60 or 70 psi shut-off3.45, 4.14 or 4.83 bar shut-off
PrimingNot self-priming; mount below the waterlineSelf-priming; mount above the waterline, not submersible
ControlFused supply; flow can be throttled with a valveIntegrated pressure switch, on demand
DutyRule's 1600 GPH manual: leave running for continuous exchange of waterIntermittent duty only
Source: xylem.com

Source: xylem.com

What size livewell pump do I need (GPH by livewell gallons)?

Multiply the livewell's capacity in gallons by the number of full water exchanges you want per hour, then choose the pump whose flow at head, not its open-flow rating, meets that number.

The rating on the box is open flow: Xylem tests Rule livewell pumps with fresh water and no ports attached. Lifting water 3.3 ft to the tank costs 15% of the 500 GPH pump's flow and 25% of the 800 and 1100 GPH pumps' flow, before hose and fitting losses.

Xylem does not publish an exchange-rate rule. The 6 to 10 exchanges per hour used below is a common working range in the trade (a full change every 6 to 10 minutes), not a Xylem figure. Use the low end for hardy fish and the high end for delicate bait or a crowded well.

Worked out from Rule's 3.3 ft figures: the 601 (425 GPH delivered) gives 10 exchanges per hour in a well up to about 42 gallons, the 603 (600 GPH) up to 60 gallons, and the 605 (825 GPH) up to about 82 gallons. At 6 exchanges per hour the same pumps cover about 70, 100 and 137 gallons.

More is not always better. Xylem states that flow is the single most important factor in bait health: too little and bait dies from lack of oxygen, too much and it dies of exhaustion fighting the current. If you are between sizes, fit the larger pump and a control valve. Rule's manuals allow a valve to regulate flow, and the 1600 GPH manual states that reducing flow with a valve will not damage the pump.

Formula

required flow at the tank (GPH) = livewell gallons x exchanges per hour

choose the pump whose GPH at 3.3 ft is equal to or greater than the result

livewell gallons
the water volume of the well or bait tank, in US gallons
exchanges per hour
6 to 10 is a general working range used in the trade, not a Xylem figure
GPH at 3.3 ft
Rule's published flow at 3.3 ft (1 m) of head: 425, 600 or 825 GPH

Worked example: A 30-gallon well at 10 exchanges per hour needs 300 GPH at the tank: the Rule 601 (425 GPH at 3.3 ft) covers it. A 60-gallon bait tank at 10 exchanges needs 600 GPH: the 603 is at its limit, so fit the 605 (825 GPH at 3.3 ft) and throttle it with a valve.

Rule Livewell Pump Series: open flow, flow at head and fuse
ModelsOpen flowFlow at 3.3 ft (1 m)Required fuseReplacement motor cartridge
601C, 601STC, 601FC500 GPH (1892 LPH)425 GPH (1609 LPH)5 A65DR
603C, 603STC, 603FC800 GPH (3028 LPH)600 GPH (2271 LPH)7.5 A66DR
605C, 605STC, 605FC1100 GPH (4163 LPH)825 GPH (3123 LPH)7.5 A67DR
Source: xylem.com

Source: xylem.com

How many amps does a livewell pump draw?

A Rule livewell pump draws 3.0 A (500 GPH), 4.1 A (800 GPH) or 4.7 A (1100 GPH) at 12 V DC. The 1600 GPH Rule 209B draws 5.0 A at 13.5 V.

Because a livewell pump runs for hours, multiply amps by hours to see what it takes from the battery. Eight hours of continuous running is 24 Ah for the 601, about 33 Ah for the 603 and about 38 Ah for the 605 (amps x hours, simple arithmetic). Going from 500 to 1100 GPH more than doubles the flow for 1.7 A more current.

Rule specifies 16 gauge wire for normal installations of the 601, 603 and 605 and 14 AWG for the 1600 GPH pump, with the fuse in the positive (brown) lead and all connections above the highest possible water level.

Rule Livewell Pump Series: current draw, inlet and discharge
ModelOpen flowAmp draw at 12 V DCFuseInletDischarge hose barb
601C500 GPH1,890 L/h3.0 A5 AAngled thru-hull, 3/4 in NPSM3/4 in19 mm
601STC500 GPH1,890 L/h3.0 A5 AStraight thru-hull, 3/4 in NPSM3/4 in19 mm
601FC500 GPH1,890 L/h3.0 A5 AStraight seacock, 3/4 in NPT3/4 in19 mm
603C800 GPH3,030 L/h4.1 A7.5 AAngled thru-hull, 3/4 in NPSM3/4 in19 mm
603STC800 GPH3,030 L/h4.1 A7.5 AStraight thru-hull, 3/4 in NPSM3/4 in19 mm
603FC800 GPH3,030 L/h4.1 A7.5 AStraight seacock, 3/4 in NPT3/4 in19 mm
605C1100 GPH4,160 L/h4.7 A7.5 AAngled thru-hull, 3/4 in NPSM1 1/8 in29 mm
605STC1100 GPH4,160 L/h4.7 A7.5 AStraight thru-hull, 3/4 in NPSM1 1/8 in29 mm
605FC1100 GPH4,160 L/h4.7 A7.5 AStraight seacock, 3/4 in NPT1 1/8 in29 mm
Source: xylem.com

Source: xylem.com

Thru-hull or seacock mount: which Rule livewell pump inlet do I need?

Pick the suffix by how the pump meets the hull: C is an angled thru-hull pickup, STC is a straight thru-hull pickup, and FC threads onto a seacock (3/4 in NPT).

The C and STC models pass through a 1 in hole in the transom or hull bottom, with the inside of the hole below the outside waterline when the boat is at rest. The FC models screw hand tight onto a seacock fed by a thru-hull pickup with a filter grate. Rule warns that the seacock must be kept closed when the livewell is not in use.

Airlocks are the usual cause of a livewell pump that runs but moves no water. Rule's instructions: keep the outlet at least parallel with the boat bottom, point the output upward if the pump is mounted horizontally, and run the hose in a constant upward direction to the tank with no dips.

For boats with high-speed pickup scoops, Xylem states that the 601, 603 and 605 are designed to withstand the pressure of high-speed water intake scoops.

  1. Measure or look up the livewell volume in gallons.
  2. Multiply by 6 to 10 exchanges per hour to get the flow needed at the tank.
  3. Choose the 601, 603 or 605 whose flow at 3.3 ft meets it.
  4. Choose the inlet: C (angled thru-hull), STC (straight thru-hull) or FC (seacock).
  5. Match the hose to the discharge barb: 3/4 in on the 601 and 603, 1 1/8 in on the 605.
  6. Fuse the positive lead at 5 A (601) or 7.5 A (603, 605) and wire with 16 gauge.

Source: xylem.com

What size washdown pump do I need (GPM and PSI)?

Choose a washdown pump by flow in GPM and shut-off pressure in psi, then check that the boat's wiring can carry its maximum current. Xylem's HD4 datasheet says that for washdown, typically, the higher the flow and the higher the pressure the better.

The Jabsco HotShot range has four steps: HotShot 3 (3 GPM, 50 psi, 7.5 A), HD4 (4 GPM, 60 psi, 11.5 A), HD5 (5 GPM, 70 psi, 16 A) and HD6 (6 GPM, 70 psi, 19.2 A). Xylem publishes no boat-length chart for these, so the matching below is our recommendation: HotShot 3 for a skiff or small bay boat with one battery, HD4 for most center consoles and cruisers up to the mid-30 ft range, and HD5 or HD6 for a 40 ft boat that washes down a large cockpit or muddy anchor chain through a long hose run.

The current matters as much as the flow. The HD6 needs a 25 A fuse and the HD5 a 20 A fuse, against 15 A for the HotShot 3 and HD4. Xylem's wire table for these pumps calls for 16 AWG up to 6 ft of total wire run, 14 AWG to 10 ft, 12 AWG to 15 ft, 10 AWG to 30 ft and 8 AWG to 40 ft, and never smaller than the pump's own leads.

Xylem's HD4 datasheet lists strainers as required in all applications and gives a maximum inlet pressure of 30 psi; every HotShot ships with a strainer.

Jabsco HotShot washdown pumps, from the Xylem HotShot brochure
Model lineModel numberOpen flowVoltageShut-off pressureMax currentRecommended fuse25 ft hose coil
HotShot 332305-5012-3A3 GPM (11 LPM)12 V DC50 psi (3.4 bar)7.5 A15 ANo
HotShot HD4Q401J-118N-3A4 GPM (15 LPM)12 V DC60 psi (4.1 bar)11.5 A15 ANo
HotShot HD4 kitQ401J-118N-4A4 GPM (15 LPM)12 V DC60 psi (4.1 bar)11.5 A15 AYes
HotShot HD4Q402J-118N-3A4 GPM (15 LPM)24 V DC60 psi (4.1 bar)6.0 A10 ANo
HotShot HD5P501J-119N-3A5 GPM (19 LPM)12 V DC70 psi (4.8 bar)16.0 A20 ANo
HotShot HD5 kitP501J-119N-4A5 GPM (19 LPM)12 V DC70 psi (4.8 bar)16.0 A20 AYes
HotShot HD6P601J-219N-3A6 GPM (23 LPM)12 V DC70 psi (4.8 bar)19.2 A25 ANo
HotShot HD6 kitP601J-219N-4A6 GPM (23 LPM)12 V DC70 psi (4.8 bar)19.2 A25 AYes
HotShot HD6P602J-219N-3A6 GPM (23 LPM)24 V DC70 psi (4.8 bar)9.4 A15 ANo
Source: xylem.com

Source: xylem.com

If your boat or use is different

For best washdown pump for most boats (center consoles and cruisers, 12 V)

Jabsco HotShot HD4 washdown kit (Q401J-118N-4A)

Our washdown pick. A 4-chamber diaphragm pump with a 60 psi pressure switch that comes as a complete kit: pump, 90 degree strainer, trigger nozzle, port fittings and a 25 ft hose coil. It primes itself from up to 8 ft, runs dry without damage, and stays on a 15 A fuse.

Specifications (8)
Open flow
4 GPM (15.1 LPM)
Pressure switch cut-off
60 psi (4.1 bar)
Max current draw
11.5 A at 60 psi
Fuse
15 A (not included)
Self-priming
Up to 8 ft (2.4 m) dry prime
Hose coil
25 ft x 0.35 in ID, 3/4 in GHT connections
Protection and approvals
ISO 8846 ignition protected, IPX6, CE and RCM marked, thermal motor protection
Warranty (HD models)
3 years
Source: xylem.com

All other rows:Source: xylem.com

For 16 ft skiff or small bay boat: livewell under about 40 gallons

Rule 601C or 601STC livewell pump (500 GPH)

The smallest pump in the series still delivers 425 GPH at 3.3 ft, which is 10 exchanges per hour in a well of about 42 gallons, and it draws 3.0 A, the lowest in the range. That matters on a single-battery boat.

Specifications (4)
Open flow
500 GPH (1892 LPH)
Flow at 3.3 ft
425 GPH (1609 LPH)
Amp draw at 12 V DC
3.0 A
Source: xylem.com
Fuse
5 A

All other rows:Source: xylem.com

For 16 ft skiff or small bay boat: washdown on a small electrical system

Jabsco HotShot 3 washdown pump (32305-5012-3A)

The lowest-current HotShot: 3 GPM at 50 psi with a 3-chamber diaphragm, an inline 40 mesh strainer and a trigger nozzle. It primes from up to 10 ft and weighs 3.2 lb. No hose coil is included.

Specifications (6)
Open flow
3 GPM (11.3 LPM)
Max operating pressure
50 psi (3.4 bar)
Max current draw
8 A at 50 psi (datasheet)7.5 A (brochure)
Fuse
15 A (not included)
Self-priming
Up to 10 ft (3 m) dry prime
Pump weight
3.2 lb (1.5 kg)

All 6 rows:Source: xylem.com

For offshore center console with a 60 to 80 gallon bait tank

Rule 605C, 605STC or 605FC livewell pump (1100 GPH)

Delivers 825 GPH at 3.3 ft, about 10 exchanges per hour in an 82 gallon tank, for 4.7 A. It uses the larger 1 1/8 in discharge barb, so plan the hose run around it.

Specifications (4)
Open flow
1100 GPH (4163 LPH)
Flow at 3.3 ft
825 GPH (3123 LPH)
Amp draw at 12 V DC
4.7 A
Source: xylem.com
Discharge hose barb
1 1/8 in
Source: xylem.com

All other rows:Source: xylem.com

For 40 ft sportfishing boat: large or multiple bait tanks on a seacock

Rule 209B and 209FDP 1600 GPH livewell/baitwell pump

The largest Rule livewell pump, which threads onto a 1 in seacock and feeds 1 1/8 in hose. The 209B has a bronze base; the 209FDP has a 1/2 in NPT second port for a washdown pump. It is ignition protected, and Rule's manual says to leave it running for continuous exchange of water.

Specifications (6)
Flow
1600 GPH (6056 LPH)
Current
5.0 A (209B), 4.9 A (209FDP), both at 13.5 V
Fuse
15 A
Wire
14 AWG (2.5 mm2) for normal installations
Connection
1 in NPT seacock, 1 1/8 in smooth wall hose
Pump type
209B bronze base, 209FDP dual port
Source: xylem.com

All other rows:Source: xylem.com

For 40 ft cruiser or sportfishing boat: anchor chain and large cockpit washdown

Jabsco HotShot HD6 washdown kit (P601J-219N-4A)

The highest flow and pressure in the range: a 5-chamber pump at 6 GPM and 70 psi, with a trigger nozzle and a 25 ft hose coil in the larger 1/2 in ID. It needs a 25 A circuit. For a 24 V boat, the P602J-219N-3A is the same pump at 9.4 A without the hose coil.

Specifications (6)
Open flow
6 GPM (22.7 LPM)
Pressure switch cut-off
70 psi (4.8 bar)
Max current draw
19 A at 70 psi
Fuse
25 A (not included)
Self-priming
Up to 7 ft (2.1 m) dry prime
Hose coil
25 ft x 1/2 in ID, 3/4 in GHT fittings

All 6 rows:Source: xylem.com

For no built-in livewell: a bucket or cooler on a jon boat, kayak or dock

Rule 202K Portable Aerator Kit

A submersible Rule 360 GPH pump on a suction-cup base that draws water from the bottom of a bucket or cooler and sends it through an adjustable spray head. It clips to the boat's battery and works in fresh or salt water. No thru-hull is needed.

Specifications (3)
Pump
Rule 360 GPH, fully submersible
Fuse
2.5 A in the positive lead
Kit contents
Pump, foam filter, suction cup base, battery clips, aerator tube, adjustable spray head

All 3 rows:Source: xylem.com

How the options compare

Livewell pumps and washdown pumps compared, as published by each manufacturer
ProductTypeOpen flowFlow at 3.3 ft head (livewell) or shut-off pressure (washdown)CurrentFuse
Rule 603C / 603STC / 603FCRuleOur pickSourceLivewell, cartridge800 GPH600 GPH4.1 A at 12 V7.5 A
Rule 601C / 601STC / 601FCRuleRecommended brandSourceLivewell, cartridge500 GPH425 GPH3.0 A at 12 V5 A
Rule 605C / 605STC / 605FCRuleRecommended brandSourceLivewell, cartridge1100 GPH825 GPH4.7 A at 12 V7.5 A
Rule 209BRuleRecommended brandSourceLivewell, non-cartridge, seacock1600 GPHNot given in the manual5.0 A at 13.5 V15 A
Johnson Pump Aqua O2 800 GPH (10-13643-01)Johnson Pump (SPX FLOW)SourceLivewell, cartridge800 GPHNot given on the product page3.7 A at 12 V5 A
Attwood Tsunami Mk2 T800 aeratorAttwoodSourceLivewell, cartridge793 GPH at 13.6 V498 GPH at 13.6 V3 A at 13.6 V, open flow4 A
Jabsco HotShot HD4 kit (Q401J-118N-4A)JabscoRecommended brandSourceWashdown, diaphragm4 GPM60 psi11.5 A max at 12 V15 A
Jabsco HotShot 3 (32305-5012-3A)JabscoRecommended brandSourceWashdown, diaphragm3 GPM50 psi7.5 A max at 12 V15 A
Jabsco HotShot HD5 kit (P501J-119N-4A)JabscoRecommended brandSourceWashdown, diaphragm5 GPM70 psi16.0 A max at 12 V20 A
Jabsco HotShot HD6 kit (P601J-219N-4A)JabscoRecommended brandSourceWashdown, diaphragm6 GPM70 psi19.2 A max at 12 V25 A
Shurflo Pro Blaster II Deluxe 4.0 (4248-153-E09)Shurflo (Pentair)SourceWashdown, diaphragm4.0 GPM60 psi10 A max at 12 VNot given on the product page
Shurflo Pro Blaster II Ultimate 5.0 (4258-153-E09)Shurflo (Pentair)SourceWashdown, diaphragm5.0 GPM60 psi14 A max at 12 VNot given on the product page
The highlighted first row is our pick. “Recommended brand” marks other products from brands the publisher recommends; the rest are rivals, each sourced to its own maker. Test voltages differ and affect both flow and current: Rule publishes the 601, 603 and 605 figures at 12 V, the 209B current at 13.5 V; the Attwood catalog figures shown are its ABYC values at 13.6 V. Attwood also publishes ISO values at 12.0 V for the T800: 2694 LPH open flow and 2142 LPH at 1 m, both at 2.5 A. Compare like with like. Rule flow at 3.3 ft is from the Rule livewell pump manual; the HD6 datasheet lists 19 A where the brochure lists 19.2 A.

Questions people ask next

Rule vs Johnson Pump vs Attwood livewell pump: which is better?

On published figures, the Rule. Rule rates every livewell model at 3.3 ft (1 m) of lift: the 800 GPH 603 delivers 600 GPH (2271 LPH) at 12 V. Attwood rates its T800 at 2142 LPH at 1 m and 12.0 V (498 GPH at 3.3 ft and 13.6 V), and Johnson Pump's Aqua O2 page gives open flow only. Every Rule model also has a 1/2 in NPT port for a washdown pump; Johnson lists that twin port on its seacock models only. The rivals lead on other points: Attwood and Johnson Pump list lower current for the 800 GPH size (2.5 A and 3.7 A against 4.1 A), Johnson Pump gives a 3 year warranty against Rule's 1 year, and Attwood's T1200 is rated above the Rule 605 at 1 m (3282 LPH against 3123 LPH).

Source: docs.navico.com

Jabsco HotShot vs Shurflo Pro Blaster II washdown pump: which is better?

For most boats, the Jabsco HotShot HD4. At the same 4 GPM (15 LPM) and 60 psi (4.1 bar) rating, Xylem rates it to self-prime from up to 8 ft (2.4 m) against 6 ft (1.82 m) for the Pro Blaster II Deluxe 4.0, and Jabsco HD models carry a 3 year warranty against the Pro Blaster II's 2 years. The Jabsco range also goes to 70 psi (4.8 bar) and 6 GPM (23 LPM). Practical Sailor, testing earlier models of both brands, noted the Shurflo ProBlaster's two-year warranty against the three years common in its test group. The Pro Blaster II draws less current: 10 A against 11.5 A at 12 V.

Source: pentair.com

Are these pumps made in 24 V, and are they CE or RCM marked for Europe and Australia?

The Jabsco HotShot HD4 is made in 12 V and 24 V (Q402J-118N-3A, 6.0 A max at 24 V), and so is the HD6 (P602J-219N-3A, 9.4 A). The HD4 datasheet lists CE and RCM marking, ISO 8846 ignition protection and IPX6. The Rule 601, 603 and 605 are listed at 12 V DC only, and Rule's livewell manual and flyer do not state CE, RCM or ISO approvals; the manual is printed in English, French, German, Italian, Dutch, Swedish and Spanish. For a 24 V boat, ask us before you order a livewell pump. Attwood lists CE, RCM and UKCA approvals for its Tsunami Mk2.

Source: xylem.com

What size livewell pump do I need for a 30 gallon livewell?

A 500 GPH (1892 LPH) pump is enough. Thirty US gallons (about 114 litres) at 10 exchanges per hour needs 300 GPH (about 1,140 LPH) at the tank, and the Rule 601 delivers 425 GPH (1609 LPH) at 3.3 ft (1 m) of head. The 6 to 10 exchanges per hour range is a general working rule, not a Xylem figure; the flow at head is Rule's published number.

Source: xylem.com

Is an aerator pump the same as a livewell pump?

In practice, yes. Both names describe a low-pressure pump that moves water into or around a livewell or baitwell, and aeration comes from that moving water breaking the surface or passing through a spray head. Rule sells its thru-hull units as livewell/baitwell pumps and its bucket unit, built around a 360 GPH pump with an adjustable spray head, as the 202K Portable Aerator Kit.

Source: xylem.com

Can I use a washdown pump as a livewell pump, or a livewell pump for washdown?

A livewell pump cannot do washdown: it makes almost no pressure, has no pressure switch and cannot prime itself. Xylem notes that a washdown pump is sometimes used with a Y valve to serve a dual purpose of livewell circulation, but HotShot pumps are rated for intermittent duty only, and a 4 GPM (15 LPM) pump moves only 240 gallons per hour (about 900 litres per hour), so we do not recommend it as the main pump for a well that needs to run all day.

Source: xylem.com

Can a livewell pump and a washdown pump share one thru-hull?

Yes, with a Rule 601, 603 or 605. Each has an extra 1/2 in NPT female port with a hex plug so a washdown pump can be added without another thru-hull fitting. On the 1600 GPH pumps, the 209FDP has the same 1/2 in port; the 209B needs a tee. Fit the washdown pump's strainer between the port and the pump.

Source: xylem.com

Should a livewell pump run continuously or on a timer?

Continuously, once fish are in the well. Rule's 1600 GPH manual says to leave the pump running for continuous exchange of water. The Keeping Bass Alive guidebook says to pump fresh water regularly and run the recirculating pump continuously in cooler water, and to close the drains and recirculate full time when surface water is above 75 F (about 24 C) for largemouth bass or 70 F (about 21 C) for smallmouth bass.

Source: dnr.maryland.gov

Why does my livewell pump run but not pump water?

Usually an airlock or a pump that is not flooded. Rule livewell pumps are not self-priming and must sit below the waterline. Rule's instructions are to keep the outlet at least parallel with the boat bottom, point the output upward on a horizontal mount, and run the hose constantly uphill to the tank with no dips. If that is all correct, close the seacock or block the thru-hull, twist out the motor cartridge and check the impeller for debris.

Source: xylem.com

What PSI should a boat washdown pump have?

Between 50 and 70 psi (3.4 to 4.8 bar). The Jabsco HotShot 3 shuts off at 50 psi (3.4 bar), the HD4 at 60 psi (4.1 bar) and the HD5 and HD6 at 70 psi (4.8 bar). Xylem's HD4 datasheet says that for washdown, typically, the higher the flow and the higher the pressure the better; the limit is the current your wiring can supply.

Source: xylem.com

Can a washdown pump run dry?

A Jabsco HotShot can. Xylem lists running dry without damage and self-priming as key features of the range. A Rule livewell pump is different: it needs flooded suction to move water at all.

Source: xylem.com

Related comparisons

Sources

This comparison relies on 25 documents, each read on the date the facts were verified. All sources in the library

List of sources (25)

If a manufacturer has changed a figure since the verified date, see how to report an error.