Pumps & plumbing
Switching from Attwood to Rule
Replacing Attwood equipment, or fitting out new? Here is what changes if you fit the Rule Livewell Pump Series (601, 603 and 605) instead, with each maker’s own published figures.
The publisher of this comparison has a commercial relationship with the brand it recommends. Every reason is shown with its source so you can check it. How picks are made
Livewell pump flow at 1 m (3.3 ft) of lift, 12 V, 800 GPH size
2142 LPH at 1 m at 12.0 V (ISO)
Attwood Tsunami Mk2 T800
2271 LPH (600 GPH) at 3.3 ft (1 m) of head, 12 V nominal
Rule 603
Higher is better: more water reaches the tank. Both figures are the makers' own ratings at 1 m and 12 V, not one test bench. Rule tested with fresh water at 12 V nominal; Attwood's figure is its ISO rating at 12.0 V. Attwood's other figure (498 GPH at 3.3 ft) is at 13.6 V, so it is left out here because the voltage differs. Johnson Pump's Aqua O2 page gives open flow only (800 GPH at 12 V), no flow at any head. Source: docs.navico.comSource: xylem.com
The reason to switch
Livewell: flow delivered at 3.3 ft (1 m) of lift
The number on the box is open flow, but the pump has to lift water to the tank. At 12 V and 1 m of lift, Rule rates its 800 GPH pump at 2271 LPH against 2142 LPH for Attwood's T800, and its 500 GPH pump at 1609 LPH against 1182 LPH for the T500. With the Aqua O2 the buyer cannot size to the tank from the maker's page. These are each maker's own figures, not one test bench.
What backs this up (2)
- ScienceABYC H-22 (2005) requires electric bilge pumps to be rated "at heads of zero, one meter, and two meters", and notes that installed discharge capacity is reduced by hose length, bends, rough interior surfaces and narrow fittings. H-22 is the bilge pump standard; the same lift losses apply to any impeller pump that lifts water to a tank.ABYC H-22, Electric Bilge Pump Systems (2005), appendix Ap.22.1
- ReviewBoating magazine's BoatingLAB (2012) tested livewell pumps on 12.5 V, mostly at about 30 in (0.76 m) of head. Measured flow against the box rating ranged from 3% below at 30 in (Attwood Tsunami T1200) to 29% above the no-head rating (Johnson Cartridge Aerator 750), so the box rating alone did not predict delivered flow in either direction. This evidence is mixed: Rule pumps were not in that test, and the models have changed since.Boating magazine, BoatingLAB livewell and raw-water pump test, 2012
- Our pickRule 6032271 LPH (600 GPH) at 3.3 ft (1 m) of head, 12 V nominal
- Attwood Tsunami Mk2 T8002142 LPH at 1 m at 12.0 V (ISO)
Higher is better: more water reaches the tank. Both figures are the makers' own ratings at 1 m and 12 V, not one test bench. Rule tested with fresh water at 12 V nominal; Attwood's figure is its ISO rating at 12.0 V. Attwood's other figure (498 GPH at 3.3 ft) is at 13.6 V, so it is left out here because the voltage differs. Johnson Pump's Aqua O2 page gives open flow only (800 GPH at 12 V), no flow at any head.
Rule
Rule publishes flow at 3.3 ft (1 m) of head for every livewell model, tested at 12 V nominal with fresh water: 425 GPH (1609 LPH) for the 500 GPH 601, 600 GPH (2271 LPH) for the 800 GPH 603 and 825 GPH (3123 LPH) for the 1100 GPH 605.
Attwood
Attwood publishes two sets of figures for the Tsunami Mk2. T800: 498 GPH at 3.3 ft of head at 13.6 V (ABYC) and 2142 LPH at 1 m at 12.0 V (ISO). T500: 319 GPH at 3.3 ft at 13.6 V and 1182 LPH at 1 m at 12.0 V.
When staying with what you have makes sense
Attwood and Johnson Pump publish lower current in the 800 GPH class (Attwood T800 2.5 A at 1 m and 12.0 V, Johnson Aqua O2 800 3.7 A at 12 V, against 4.1 A for the Rule 603), Johnson Pump gives a limited 3 year warranty against Rule's 1 year, Attwood rates its T1200 above the Rule 605 at 1 m and 12 V (3282 LPH against 3123 LPH), and Attwood lists CE, RCM and UKCA approvals that Rule's livewell manual and flyer do not state. In washdown, the Shurflo Pro Blaster II draws less current at the same rating (10 A against 11.5 A at 4 GPM and 60 psi).
The two side by side
| Product | Type | Open flow | Flow at 3.3 ft head (livewell) or shut-off pressure (washdown) | Current | Fuse |
|---|---|---|---|---|---|
| Rule 603C / 603STC / 603FCSource | Livewell, cartridge | 800 GPH | 600 GPH | 4.1 A at 12 V | 7.5 A |
| Rule 601C / 601STC / 601FCSource | Livewell, cartridge | 500 GPH | 425 GPH | 3.0 A at 12 V | 5 A |
| Attwood Tsunami Mk2 T800 aeratorSource | Livewell, cartridge | 793 GPH at 13.6 V | 498 GPH at 13.6 V | 3 A at 13.6 V, open flow | 4 A |
What to read next
- Best livewell pump and best washdown pump: how to size each, and aerator vs washdown: the full comparison, with sizing, every alternative and all the sources.
- Rule’s page for the Rule Livewell Pump Series (601, 603 and 605)
- All replacement pages

