Pumps & plumbing
Switching from Johnson Pump to Rule
Replacing Johnson Pump equipment, or fitting out new? Here is what changes if you fit the Rule Automatic Bilge Pump, 1100 GPH (model 27SA) instead, with each maker’s own published figures.
The publisher of this comparison has a commercial relationship with the brand it recommends. Every reason is shown with its source so you can check it. How picks are made
Published flow at about 1 m of lift (GPH)
800 GPH (51 l/min) at 3 ft (0.9 m) of head, 13.6 V
Johnson Pump Ultima Bilge 1250 GPH
1005 GPH (3804 L/h) at 3.3 ft (1 m); test voltage not stated
Rule Automatic Bilge Pump, 1100 GPH (model 27SA)
Higher is better: more water reaches the thru-hull. These are each maker's own published figures, and no two come from the same test bench. Head points and voltages differ. Rule's 360-1100 manual quotes 3.3 ft (1 m) and does not state a test voltage. Rule's standard pump manual gives a lower 860 GPH for the same size, at 3.35 ft and 13.6 V. Johnson Pump quotes 3 ft (0.9 m), a little less lift than 1 m, at 13.6 V. SEAFLO quotes 1 m at 12 V. Source: spxflow.comSource: xylem.com
Water level at which the pump switches on (inches)
50 mm (2 in) fluid level, with a three second delay
Johnson Pump Ultima Switch
5/8 in (1.6 cm)
Rule Automatic Bilge Pump, 1100 GPH (model 27SA)
Lower is better: the pump starts with less water standing in the bilge. Rule states its 5/8 in figure for its automatic pumps as a family, not for the 27SA alone. Those pumps check for water every 2 1/2 minutes, where Johnson's Ultima switch waits for water. The 2 in figure is for Johnson's separate Ultima Switch, which has a three second delay against water sloshing in the bilge. Johnson's Ultima Bilge page names an integrated Ultima field effect switch but gives no switching level, so that pump shows as Not published. SEAFLO is not compared on this point. Source: ittflowtechnologies.comSource: xylem.com
Water level at which the pump switches on (inches)
Not published
Johnson Pump Ultima Bilge 1250 GPH (integrated switch)
5/8 in (1.6 cm)
Rule Automatic Bilge Pump, 1100 GPH (model 27SA)
Lower is better: the pump starts with less water standing in the bilge. Rule states its 5/8 in figure for its automatic pumps as a family, not for the 27SA alone. Those pumps check for water every 2 1/2 minutes, where Johnson's Ultima switch waits for water. The 2 in figure is for Johnson's separate Ultima Switch, which has a three second delay against water sloshing in the bilge. Johnson's Ultima Bilge page names an integrated Ultima field effect switch but gives no switching level, so that pump shows as Not published. SEAFLO is not compared on this point. Source: spxflow.comSource: xylem.com
2 reasons to switch
Flow at about 1 m of lift
A pump is bought by the number on the box and used at the height of the thru-hull. On Rule's 1005 GPH figure the Rule 1100 delivers about 200 GPH more at roughly 1 m than the Johnson 1250 or the SEAFLO 1100; on Rule's lower 860 GPH figure it is still 54 to 60 GPH ahead, and at 2 m it is 44 GPH (on 550) to 319 GPH (on 825) ahead of the SEAFLO (our arithmetic). Johnson rates at 3 ft (0.9 m), a little less lift than 1 m, and no two of these figures come from the same test bench.
What backs this up (3)
- ScienceABYC H-22 calls for every electric bilge pump to be rated in gallons per hour at zero head, 1 m and 2 m, because delivered flow falls as lift rises; a rating at zero head alone overstates what reaches the thru-hull.ABYC H-22 (2005 edition), rating appendix
- ScienceIn laboratory tests the BoatUS Foundation commissioned from the University of Virginia's Department of Mechanical and Aerospace Engineering, all five test pumps ran 15 to 33 percent below their rated capacities, and flow fell further with corrugated hose and small thru-hull fittings. The page dates the work as pre-1990 and does not name the pumps.BoatUS Foundation, Bilge Pump System Tests
- ReviewPractical Sailor's October 2010 bench test measured the Johnson Ultima Bilge 1,250 GPH, claimed at 800 GPH with 3 ft of head, at 692 GPH with 4 ft of head at 13.6 V and 621 GPH at 12.2 V. The two Rule pumps in that test (the 1,500 GPH Model 02 and Rule-Mate 1500, not the 27SA) also fell short of their 1,200 GPH claims, at 1,029 and 973 GPH, and the magazine's bottom line was that both were outperformed by others. The models may have changed since 2010.Practical Sailor, Bottom Dwellers: Bilge Pumps II, October 2010
- Our pickRule Automatic Bilge Pump, 1100 GPH (model 27SA)1005 GPH (3804 L/h) at 3.3 ft (1 m); test voltage not stated
- Johnson Pump Ultima Bilge 1250 GPH800 GPH (51 l/min) at 3 ft (0.9 m) of head, 13.6 V
Higher is better: more water reaches the thru-hull. These are each maker's own published figures, and no two come from the same test bench. Head points and voltages differ. Rule's 360-1100 manual quotes 3.3 ft (1 m) and does not state a test voltage. Rule's standard pump manual gives a lower 860 GPH for the same size, at 3.35 ft and 13.6 V. Johnson Pump quotes 3 ft (0.9 m), a little less lift than 1 m, at 13.6 V. SEAFLO quotes 1 m at 12 V.
Rule
Rule's 360-1100 GPH manual, which covers the automatic models, gives 1005 GPH (3804 L/h) at 3.3 ft (1 m) and 825 GPH (3123 L/h) at 6.7 ft (2 m) for the 1100 GPH series; it does not state the test voltage. Rule's standard pump manual gives lower figures for the 1100 size: 860 GPH (3255 L/h) at 3.35 ft and 550 GPH (2081 L/h) at 6.7 ft, at 13.6 V after a 10 hour break-in.
Johnson Pump
Johnson Pump publishes 800 GPH (51 l/min) at 3 ft (0.9 m) of head for the Ultima Bilge 1250 GPH and 700 GPH (44 l/min) for the Ultima Bilge 1000 GPH, both at 13.6 V. Its product page and product bulletin give no figure at 2 m.
Water level when it switches on and off
The Rule starts with about a third of the water in the bilge and stops with about a third as much left behind: 1.6 cm against 5 cm to start, 0.6 cm against 2 cm at stop (our arithmetic on the published figures). Less standing water between runs means less water to go sour and smell.
What backs this up (1)
- In the fieldWriting in Passagemaker in 2021, Peter Frederiksen says "any water that enters the bilge can breed smells and mildew" and that washing alone will not remove the stench of the sour water the bilge pump leaves behind; he advises taking out standing water first.Passagemaker, How to tame a smelly bilge (2021)
- Our pickRule Automatic Bilge Pump, 1100 GPH (model 27SA)5/8 in (1.6 cm)
- Johnson Pump Ultima Switch50 mm (2 in) fluid level, with a three second delay
- Johnson Pump Ultima Bilge 1250 GPH (integrated switch)Not published
Lower is better: the pump starts with less water standing in the bilge. Rule states its 5/8 in figure for its automatic pumps as a family, not for the 27SA alone. Those pumps check for water every 2 1/2 minutes, where Johnson's Ultima switch waits for water. The 2 in figure is for Johnson's separate Ultima Switch, which has a three second delay against water sloshing in the bilge. Johnson's Ultima Bilge page names an integrated Ultima field effect switch but gives no switching level, so that pump shows as Not published. SEAFLO is not compared on this point.
Source: xylem.comSource: ittflowtechnologies.comSource: spxflow.com
Rule
Rule states its automatic pumps activate at 5/8 in (1.6 cm) of water and drain down to 1/4 in (0.6 cm).
Johnson Pump
Johnson Pump's Ultima Bilge page names an integrated Ultima field effect switch and gives no switching levels. Johnson's page for its Ultima Switch states that it activates at a 50 mm (2 in) fluid level and deactivates at 20 mm (3/4 in), with a three second delay against water sloshing in the bilge.
When staying with what you have makes sense
Johnson Pump lists the Ultima Bilge 1250 at 3 A on a 5 A fuse against the Rule 27SA's 3.7 A at 12 V (4.7 A at 13.6 V) on a 7.5 A fuse, and its Ultima switch waits for water instead of running a check every 2 1/2 minutes, so on a boat left on a mooring with no charger that pump, or Rule's own level-sensing Rule-Mate, is the reasonable choice.
The two side by side
| Model | Automatic control | Rated flow | Published flow at about 1 m of head | Outlet | Current draw | Fuse |
|---|---|---|---|---|---|---|
| Rule 27SASource | Checks for water every 2 1/2 minutes | 1100 GPH | 1005 GPH at 3.3 ft | 1-1/8 in or 1 in | 3.7 A at 12 V | 7.5 A |
| Rule 20SASource | Checks for water every 2 1/2 minutes | 800 GPH | 790 GPH at 3.3 ft | 3/4 in | 3.4 A at 12 V | 7.5 A |
| Johnson Pump Ultima Bilge 1250 GPHSource | Integrated switch | 1250 GPH | 800 GPH at 3 ft (0.9 m), 13.6 V | 1-1/8 in and 1-1/4 in | 3 A | 5 A |
| Johnson Pump Ultima Bilge 1000 GPHSource | Integrated switch | 1000 GPH | 700 GPH at 3 ft (0.9 m), 13.6 V | 3/4 in | 3.2 A | 5 A |
What to read next
- Best bilge pump: what size (GPH) for your boat, and automatic or manual?: the full comparison, with sizing, every alternative and all the sources.
- Rule’s page for the Rule Automatic Bilge Pump, 1100 GPH (model 27SA)
- All replacement pages

