Pumps & plumbing
Switching from Johnson Pump to Rule
Replacing Johnson Pump equipment, or fitting out new? Here is what changes if you fit the Rule Livewell Pump Series (601, 603 and 605) instead, with each maker’s own published figures.
The publisher of this comparison has a commercial relationship with the brand it recommends. Every reason is shown with its source so you can check it. How picks are made
Livewell pump flow at 1 m (3.3 ft) of lift, 12 V, 800 GPH size
Not published (open flow only)
Johnson Pump Aqua O2 800 GPH
2271 LPH (600 GPH) at 3.3 ft (1 m) of head, 12 V nominal
Rule 603
Higher is better: more water reaches the tank. Both figures are the makers' own ratings at 1 m and 12 V, not one test bench. Rule tested with fresh water at 12 V nominal; Attwood's figure is its ISO rating at 12.0 V. Attwood's other figure (498 GPH at 3.3 ft) is at 13.6 V, so it is left out here because the voltage differs. Johnson Pump's Aqua O2 page gives open flow only (800 GPH at 12 V), no flow at any head. Source: ittflowtechnologies.comSource: xylem.com
2 reasons to switch
Livewell: flow delivered at 3.3 ft (1 m) of lift
The number on the box is open flow, but the pump has to lift water to the tank. At 12 V and 1 m of lift, Rule rates its 800 GPH pump at 2271 LPH against 2142 LPH for Attwood's T800, and its 500 GPH pump at 1609 LPH against 1182 LPH for the T500. With the Aqua O2 the buyer cannot size to the tank from the maker's page. These are each maker's own figures, not one test bench.
What backs this up (2)
- ScienceABYC H-22 (2005) requires electric bilge pumps to be rated "at heads of zero, one meter, and two meters", and notes that installed discharge capacity is reduced by hose length, bends, rough interior surfaces and narrow fittings. H-22 is the bilge pump standard; the same lift losses apply to any impeller pump that lifts water to a tank.ABYC H-22, Electric Bilge Pump Systems (2005), appendix Ap.22.1
- ReviewBoating magazine's BoatingLAB (2012) tested livewell pumps on 12.5 V, mostly at about 30 in (0.76 m) of head. Measured flow against the box rating ranged from 3% below at 30 in (Attwood Tsunami T1200) to 29% above the no-head rating (Johnson Cartridge Aerator 750), so the box rating alone did not predict delivered flow in either direction. This evidence is mixed: Rule pumps were not in that test, and the models have changed since.Boating magazine, BoatingLAB livewell and raw-water pump test, 2012
- Our pickRule 6032271 LPH (600 GPH) at 3.3 ft (1 m) of head, 12 V nominal
- Johnson Pump Aqua O2 800 GPHNot published (open flow only)
Higher is better: more water reaches the tank. Both figures are the makers' own ratings at 1 m and 12 V, not one test bench. Rule tested with fresh water at 12 V nominal; Attwood's figure is its ISO rating at 12.0 V. Attwood's other figure (498 GPH at 3.3 ft) is at 13.6 V, so it is left out here because the voltage differs. Johnson Pump's Aqua O2 page gives open flow only (800 GPH at 12 V), no flow at any head.
Rule
Rule publishes flow at 3.3 ft (1 m) of head for every livewell model, tested at 12 V nominal with fresh water: 425 GPH (1609 LPH) for the 500 GPH 601, 600 GPH (2271 LPH) for the 800 GPH 603 and 825 GPH (3123 LPH) for the 1100 GPH 605.
Johnson Pump
Johnson Pump's Aqua O2 product page lists open flow only (500 GPH and 800 GPH at 12 V). It states no flow figure at any head, and it links no manual.
Livewell: second port for a washdown pump on every model
On a boat where the livewell pump goes straight through the transom or the bottom, a Rule lets the livewell pump and the washdown pump share one hole in the hull. Every fitting below the waterline is one more seal, hose and clamp to inspect.
What backs this up (2)
- In the fieldBoatUS's review of its insurance claim files found that 69% of sinkings happened at the dock or mooring, and 39% of those when "some small part gives up the fight with water due to wear, tear and corrosion". Its advice is to inspect all below-waterline fittings, hoses and clamps each season.BoatUS claim files, reported by Sail-World, 2014
- In the fieldOn the iBoats forum (2005), the owner of a 1989 20 ft (6.1 m) Grady-White asked how to feed a livewell pump and a washdown pump from one thru-hull; another owner described one transom thru-hull feeding two pumps, one for washdown and one for the aerator.iBoats forum owner thread, Livewell/Washdown Install Question
Rule
Every Rule 601, 603 and 605, including the thru-hull models, is fitted with an additional 1/2 in NPT female port and hex plug, so a washdown pump can be added without another thru-hull fitting.
Johnson Pump
Johnson Pump lists the Aqua O2 twin port on its seacock models (10-13649-01 and 10-13650-01). The page does not list a twin port for its thru-hull models (10-13642-01 and 10-13643-01).
When staying with what you have makes sense
Attwood and Johnson Pump publish lower current in the 800 GPH class (Attwood T800 2.5 A at 1 m and 12.0 V, Johnson Aqua O2 800 3.7 A at 12 V, against 4.1 A for the Rule 603), Johnson Pump gives a limited 3 year warranty against Rule's 1 year, Attwood rates its T1200 above the Rule 605 at 1 m and 12 V (3282 LPH against 3123 LPH), and Attwood lists CE, RCM and UKCA approvals that Rule's livewell manual and flyer do not state. In washdown, the Shurflo Pro Blaster II draws less current at the same rating (10 A against 11.5 A at 4 GPM and 60 psi).
The two side by side
| Product | Type | Open flow | Flow at 3.3 ft head (livewell) or shut-off pressure (washdown) | Current | Fuse |
|---|---|---|---|---|---|
| Rule 603C / 603STC / 603FCSource | Livewell, cartridge | 800 GPH | 600 GPH | 4.1 A at 12 V | 7.5 A |
| Rule 601C / 601STC / 601FCSource | Livewell, cartridge | 500 GPH | 425 GPH | 3.0 A at 12 V | 5 A |
| Johnson Pump Aqua O2 800 GPH (10-13643-01)Source | Livewell, cartridge | 800 GPH | Not given on the product page | 3.7 A at 12 V | 5 A |
What to read next
- Best livewell pump and best washdown pump: how to size each, and aerator vs washdown: the full comparison, with sizing, every alternative and all the sources.
- Rule’s page for the Rule Livewell Pump Series (601, 603 and 605)
- All replacement pages

