Pumps & plumbing
Switching from SEAFLO to Rule
Replacing SEAFLO equipment, or fitting out new? Here is what changes if you fit the Rule Automatic Bilge Pump, 1100 GPH (model 27SA) instead, with each maker’s own published figures.
The publisher of this comparison has a commercial relationship with the brand it recommends. Every reason is shown with its source so you can check it. How picks are made
Published flow at about 1 m of lift (GPH)
806 GPH (3050 LPH) at 1 m, 12 V
SEAFLO 11 Series 1100 GPH (SFBP1-G1100-11)
1005 GPH (3804 L/h) at 3.3 ft (1 m); test voltage not stated
Rule Automatic Bilge Pump, 1100 GPH (model 27SA)
Higher is better: more water reaches the thru-hull. These are each maker's own published figures, and no two come from the same test bench. Head points and voltages differ. Rule's 360-1100 manual quotes 3.3 ft (1 m) and does not state a test voltage. Rule's standard pump manual gives a lower 860 GPH for the same size, at 3.35 ft and 13.6 V. Johnson Pump quotes 3 ft (0.9 m), a little less lift than 1 m, at 13.6 V. SEAFLO quotes 1 m at 12 V. Source: seaflo.comSource: xylem.com
2 reasons to switch
Flow at about 1 m of lift
A pump is bought by the number on the box and used at the height of the thru-hull. On Rule's 1005 GPH figure the Rule 1100 delivers about 200 GPH more at roughly 1 m than the Johnson 1250 or the SEAFLO 1100; on Rule's lower 860 GPH figure it is still 54 to 60 GPH ahead, and at 2 m it is 44 GPH (on 550) to 319 GPH (on 825) ahead of the SEAFLO (our arithmetic). Johnson rates at 3 ft (0.9 m), a little less lift than 1 m, and no two of these figures come from the same test bench.
What backs this up (3)
- ScienceABYC H-22 calls for every electric bilge pump to be rated in gallons per hour at zero head, 1 m and 2 m, because delivered flow falls as lift rises; a rating at zero head alone overstates what reaches the thru-hull.ABYC H-22 (2005 edition), rating appendix
- ScienceIn laboratory tests the BoatUS Foundation commissioned from the University of Virginia's Department of Mechanical and Aerospace Engineering, all five test pumps ran 15 to 33 percent below their rated capacities, and flow fell further with corrugated hose and small thru-hull fittings. The page dates the work as pre-1990 and does not name the pumps.BoatUS Foundation, Bilge Pump System Tests
- ReviewPractical Sailor's October 2010 bench test measured the Johnson Ultima Bilge 1,250 GPH, claimed at 800 GPH with 3 ft of head, at 692 GPH with 4 ft of head at 13.6 V and 621 GPH at 12.2 V. The two Rule pumps in that test (the 1,500 GPH Model 02 and Rule-Mate 1500, not the 27SA) also fell short of their 1,200 GPH claims, at 1,029 and 973 GPH, and the magazine's bottom line was that both were outperformed by others. The models may have changed since 2010.Practical Sailor, Bottom Dwellers: Bilge Pumps II, October 2010
- Our pickRule Automatic Bilge Pump, 1100 GPH (model 27SA)1005 GPH (3804 L/h) at 3.3 ft (1 m); test voltage not stated
- SEAFLO 11 Series 1100 GPH (SFBP1-G1100-11)806 GPH (3050 LPH) at 1 m, 12 V
Higher is better: more water reaches the thru-hull. These are each maker's own published figures, and no two come from the same test bench. Head points and voltages differ. Rule's 360-1100 manual quotes 3.3 ft (1 m) and does not state a test voltage. Rule's standard pump manual gives a lower 860 GPH for the same size, at 3.35 ft and 13.6 V. Johnson Pump quotes 3 ft (0.9 m), a little less lift than 1 m, at 13.6 V. SEAFLO quotes 1 m at 12 V.
Rule
Rule's 360-1100 GPH manual, which covers the automatic models, gives 1005 GPH (3804 L/h) at 3.3 ft (1 m) and 825 GPH (3123 L/h) at 6.7 ft (2 m) for the 1100 GPH series; it does not state the test voltage. Rule's standard pump manual gives lower figures for the 1100 size: 860 GPH (3255 L/h) at 3.35 ft and 550 GPH (2081 L/h) at 6.7 ft, at 13.6 V after a 10 hour break-in.
SEAFLO
SEAFLO publishes 806 GPH (3050 LPH) at 1 m and 506 GPH (1915 LPH) at 2 m for the 11 Series 1100 GPH pump (SFBP1-G1100-11) at 12 V.
Switching with no float
A float is a moving part that sits in the dirtiest water on the boat. The Rule has nothing in the bilge to lift, stick or foul; it decides by the load on its own impeller. The accounts below are about float switches in general, not about the SEAFLO pump.
What backs this up (3)
- ReviewPractical Sailor's 2010 installation advice says a pump's water sensor should resist fouling and that "common float switches should be in a housing" because otherwise they are more prone to fouling by debris.Practical Sailor, Rules of Thumb for Bilge Pump Installations, October 2010
- In the fieldCottage Life (Canada) warns that debris can stop a float switch from lifting to start the pump, or from dropping again to stop it, and advises lifting the float by hand to test it.Cottage Life, What to do if your bilge pump fails (October 2025)
- In the fieldOn The Tugnuts owners' forum in June 2019, a Ranger 31 owner reported a failed float sensor, and another owner blamed paint flakes from engine hoses: "These paint chips are very efficient at fouling the float." These are single owners' accounts.The Tugnuts forum, Failed Float Switch (2019)
Rule
Rule automatic pumps need no float switch: the pump turns on for about a second every 2 1/2 minutes, measures the load on the impeller, and keeps running until the water is removed.
SEAFLO
SEAFLO describes the 11 Series 1100 GPH as an all-in-one pump with a built-in magnetic float switch, which turns the pump on when the water level rises and off when the water is removed.
When staying with what you have makes sense
Johnson Pump lists the Ultima Bilge 1250 at 3 A on a 5 A fuse against the Rule 27SA's 3.7 A at 12 V (4.7 A at 13.6 V) on a 7.5 A fuse, and its Ultima switch waits for water instead of running a check every 2 1/2 minutes, so on a boat left on a mooring with no charger that pump, or Rule's own level-sensing Rule-Mate, is the reasonable choice.
The two side by side
| Model | Automatic control | Rated flow | Published flow at about 1 m of head | Outlet | Current draw | Fuse |
|---|---|---|---|---|---|---|
| Rule 27SASource | Checks for water every 2 1/2 minutes | 1100 GPH | 1005 GPH at 3.3 ft | 1-1/8 in or 1 in | 3.7 A at 12 V | 7.5 A |
| Rule 20SASource | Checks for water every 2 1/2 minutes | 800 GPH | 790 GPH at 3.3 ft | 3/4 in | 3.4 A at 12 V | 7.5 A |
| SEAFLO 11 Series 1100 GPH (SFBP1-G1100-11)Source | Built-in magnetic float switch | 1100 GPH | 806 GPH at 1 m (12 V) | 1-1/8 in (29 mm) | 3.0 A | Not stated; 5.0 A maximum draw |
| SEAFLO 11 Series 750 GPH (SFBP1-G750-11)Source | Built-in magnetic float switch | 750 GPH | 504 GPH at 1 m (12 V) | 3/4 in (19 mm) | 3.0 A | Not stated; 5.0 A maximum draw |
What to read next
- Best bilge pump: what size (GPH) for your boat, and automatic or manual?: the full comparison, with sizing, every alternative and all the sources.
- Rule’s page for the Rule Automatic Bilge Pump, 1100 GPH (model 27SA)
- All replacement pages